    Furnace blower must be switched on manually
    Hi,
    I have a Williamson "Temp-o-matic" forced air oil furnace. I just recently purchased the house and when I went to change the thermostat it only had two wires wired to it (just a 2 conductor wire with no other wiring). When I connect those two wires together, the furnace comes on and generates heat. I noticed that the blower motor never came on to push heat in to the house.
    During further inspection, I found a standard style light switch on the side of the furnace that would turn the blower on and off at any given time. There are no unattached wires anywhere near the furnace.

    I ran a new 6 conductor wire to the furnace when I replaced the thermostat, but I don't know what to do to get the blower to come on automatically?

    Thanks in advance,
    Marty
    :cool:
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Oct 11, 2007, 11:25 PM
    You may have a defective fan and limit control. Williamson oil equiptment use this style to control the blower and also to shut the burner off if the temp went to high as in when the blower does not work. It is usually a honeywell control mounted on the upper face of the furnace above the burner. You can test this control if you have a meter. Also this control sometimes has a white push pull control to allow manual operation of the blower or automatic. If you look in the sticky notes at the beginning of this section there might be some info there for you to read about this control.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Wiring a furnace thermostat to manually operate the furnace fan [ 2 Answers ]

I have two wires connected to my furnace thermostat. There is a place labeled G on the thermostat. Can I simply run a wire from the G terminal on my thermostat to the terminal labeled G on my furnace fan relay to operate the fan separately?

Goodman furnace GMNT080-4 furnace runs good for a while then has to be manually reset [ 5 Answers ]

I have a Goodman GMNT080-4 (90%). I'm having the same problem As Streatherg did back in the Nov 2006 question. I reviewed his article and tried Every thing on there but seems to be doing the same thing. The furnace kicks on for about an hour then locks out and has to be manually reset threw...

Furnace blower goes on and off [ 2 Answers ]

Hi, I Have A Ultra80 Upflow Forced Hot Air Furnace... my?? To You Is... burner Comes On... then Blower Starts-runs For About A Minute Then Shuts Off.. burners Still Running Then Blower Comes On Again And Shuts Off... the Furnace Its Self If Hot As Heck... so What Im Saying Is The Blower Cycles On...

My Furnace won't kick on even after I've manually primed it 10 times [ 1 Answers ]

I need to know why I can't seem to keep the furnace running I prime it it stays on for 2 minutes then shuts down even before the blower starts . What's up with the red light near the reset button

Furnace/blower. [ 6 Answers ]

Been searching but so far I haven't found any information that really helps me. I've lived in this house for about a year and a half now, it has the original furance in it(house was built in the 70's I blelieve). Last year the furnace worked fine, and had worked fine so far this year. I live in...


View more questions Search