Ask Experts Questions for FREE Help!
Answer   ||    Advanced Search

Ask your question or search...
International Sites: Nederlandse experts vragen
User Name 
Password 
Join   Forgot password? 

Home > Home & Garden > Heating & Air Conditioning   »   Fan on electric heat/cooling unit will not kick off

Question
 
 
#1  
Old May 27, 2009, 07:03 PM
noideaburrow
New Member
noideaburrow is offline
 
Join Date: May 2009
Posts: 5
noideaburrow See this member's comment history on his/her Profile page.
Fan on electric heat/cooling unit will not kick off

our electric heating cooling unit continuously runs. during the winter we had to run the heat on emergency heat because the unit would not kick, the house always stayed comfortable. now we have attempted to run the unit the last 2days (for the first time for this spring) it cools very well but the fan runs continuously and last night the pipes that are inside (where the filter area is located) frozen up.
noidea burrow

Reply With Quote
 
     

Answers
 
 
Old May 27, 2009, 07:34 PM   #2  
Heating and Air Conditioning Expert
letmetellu is offline
 
Join Date: Dec 2005
Location: Texas
Posts: 2,849
letmetellu See this member's comment history on his/her Profile page.letmetellu See this member's comment history on his/her Profile page.letmetellu See this member's comment history on his/her Profile page.
My first thought would be that the contactor in the out door unit has the points stuck together. Can you turn the unit off from the thermostat? If not it could also be a short between the wire on the Y terminal and the wire from the R terminal in the thermostat.

Tell me a little about the AC, does it cycle off and on by the thermostat but the fan keeps running or does the AC not cycle off and on.

Comments on this post
noideaburrow agrees: right on point it was the contactor perfect 10, thanks for your help!!!!!
  Reply With Quote
 
     
 
 
Old May 28, 2009, 07:00 PM   #3  
New Member
noideaburrow is offline
 
Join Date: May 2009
Posts: 5
noideaburrow See this member's comment history on his/her Profile page.
thanks for reviewing my question, to tell you alittle about my unit as letmetellu requested. It is a Carrier Unit I am not sure of the age we just purchased last yr. The answer to your question: yes you can turn the unit off by the thermostat and the fan does continue to run, and yes it cycles on and off by the thermostat and the fan continues to run. I read on the inside unit some electrically plate on the unit it has a Supply Circuit-Dual. I really do not know if that information is relevant. thanks again and i appreciate your feedback!
  Reply With Quote
 
     
 
 
Old May 28, 2009, 07:01 PM   #4  
Ultra Member
Joshdta is offline
 
Joshdta's Avatar
 
Join Date: Apr 2009
Location: West Virginia
Posts: 1,618
Joshdta See this member's comment history on his/her Profile page.
Send a message via AIM to Joshdta
The indoor fan always runs or the outdoor fan??? If it is the oudoor unit, i agree it is probally the concactor
  Reply With Quote
 
     
 
 
Old May 28, 2009, 07:15 PM   #5  
Ultra Member
T-Top is offline
 
Join Date: Nov 2006
Posts: 1,160
T-Top See this member's comment history on his/her Profile page.
If you had a high electric bill in the winter and the unit never shut off, the electric heat strips was taking over because the heat pump was not able to take the load. If it runs all the time in cooling and not doing its job and the refrigeration line is freezing up you got a problem: Air flow or low on refrigerant. By the way your describing it I would say its low on refrigerant.
  Reply With Quote
 
     
 
 
Old May 28, 2009, 07:26 PM   #6  
New Member
noideaburrow is offline
 
Join Date: May 2009
Posts: 5
noideaburrow See this member's comment history on his/her Profile page.
Joshdta, it is the outside unit that continues to run. What is the contactor? How can this be tested to find out if it is the problem? Thanks for the feedback!
  Reply With Quote
 
     
 
 
Old May 28, 2009, 07:33 PM   #7  
New Member
noideaburrow is offline
 
Join Date: May 2009
Posts: 5
noideaburrow See this member's comment history on his/her Profile page.
electric bill was high at first, until we started the emergency heat, the cooling works good and then i believe when the thermostat mode is turned to off the vents have warm air blowing out, the blowing from the vent is not a normal blowing pressure but is very little pressure......no idea and i do not know any a/c terms yet still learning
  Reply With Quote
 
     
 
 
Old May 28, 2009, 07:41 PM   #8  
Ultra Member
T-Top is offline
 
Join Date: Nov 2006
Posts: 1,160
T-Top See this member's comment history on his/her Profile page.
If the out side system runs after you turn the thermostat to off. you have a bad contactor(stuck closed).
  Reply With Quote
 
     
 
 
Old May 29, 2009, 04:36 AM   #9  
Ultra Member
Joshdta is offline
 
Joshdta's Avatar
 
Join Date: Apr 2009
Location: West Virginia
Posts: 1,618
Joshdta See this member's comment history on his/her Profile page.
Send a message via AIM to Joshdta
http://yueqing-shi-shinaidi-electric...ges/283101.jpg

see the small two buttons in the middle?? after you turn the t-stat off these should pop back out, if the dont then they are stuck closed. TURN THE 220 VOLT POWER OFF and the t-stat and try poking them with a screw driver you may be able to free them, but odds are you will need a new contactor.

Comments on this post
noideaburrow agrees: the contactor was fired, had to replace, great answer!!!!!
  Reply With Quote
 
     
 
 
Old May 29, 2009, 04:55 AM   #10  
Junior Member
mower_man is offline
 
Join Date: Jan 2009
Location: 1592 hwy.ch.rd,Elgin,South carolina
Posts: 81
mower_man See this member's comment history on his/her Profile page.
You might need freon.

Reply Soon!

Mower_Man!

P.S:Ballengerb1 Dosen't Know His Facts!!
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login



Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes
Ask your question or search...



Similar Threads
changed from separate cooling & heating unit to combined unit
(1 replies)
heat pump , in cooling cyce unit runs no cold air
(1 replies)
Coleman Evcon Electric Heat/Air unit filter placement
(1 replies)
mobile home cooling unit not cooling
(1 replies)
When A/C unit comes on, outside fan doesn't always kick on
(3 replies)

Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page
Search this Thread

Advanced Search

Bookmarks





Copyright ©2003 - 2009, Ask Me Help Desk.