    A different Honeywell RTH3100C installation question - W2 wire?
    "What to do with the W2 (and maybe W1) wire?"

    I am replacing an old Payne thermostat that controlled a heat pump system which provides heating and cooling, along with "emergency heat". The new unit is a Honeywell RTH3100C.

    I labeled all the wires as I removed the wires that were attached to the Payne unit (there were two wires that were not used in the old installation which remain unconnected in the new installation). I attached the wires (WIRE) to the wiring block of Honeywell unit (BLOCK) as follows:

    B - W
    L - I
    O - R
    C - E
    K
    ====
    E - E
    Aux- W1 (not sure if this is correct; manual states Aux, W, W1, or W2)
    Y - Y
    G - G (manual indicates F could alternatively be connected here if no G)
    O - O
    L - F (manual indicates F could alternatively be connected if no L)
    R - R
    B - n/c (I don't have B or H wires in the old thermostat connection)
    C - n/c (not req'd for new thermo w/ batteries; old thermo had no B or X wires)

    The manual said that if the old thermostat had w1, w2 and y wires (which it does), I need to contact a heating cooling contractor for help. I've got a W2 with no obvious connection (I connected the W1 to the Aux connection). What, if anything, should the W2 be connected to?

    The heat pump consists of a coil unit, BDP (Carrier?) 541CB048 and the main blower/aux heater, BDP (Carrier) 517EN048.

    The old thermostat was a BDP Co (Payne) 34427DP117. The wires were connected to G, Y, E, O, W1, W2, F, R

    I'd really appreciate any insight you can give me -- it's starting to get cold :)
    labman's Avatar
    labman Posts: 10,580, Reputation: 551
    Uber Member
     
    #2

    Nov 1, 2006, 08:06 PM
    ====
    E - E
    ?
    Aux- W1 (not sure if this is correct; manual states Aux, W, W1, or W2)
    This should contorl the emergency resistance heat

    Y - Y
    This starts the outside unit for heat or cooling

    G - G (manual indicates F could alternatively be connected here if no G)
    This is fan on

    O - O
    This controls the reversing valves that control heating and cooling.

    L - F (manual indicates F could alternatively be connected if no L)
    This may be the regular heat. Maybe mixed up with W1

    R - R
    Hot from the transformer

    B - n/c (I don't have B or H wires in the old thermostat connection)
    ?
    C - n/c (
    Common, other side of the transformer, needed in some cases to power the thermostat.

    Maybe this will help, and maybe somebody that knows more about heat pumps will have to help. Doing what I can.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Janitrol 7 wire to Honeywell RTH230B 5 wire [ 3 Answers ]

I currently have a Janitrol digital thermostat. I can't read the model #. It has 8 terminals and 7 wires hooked up. Terminal - Color Y - Yellow Com - Blue R - Red G - Green w2 - Looks white E/w3 - Looks pink O - Orange B - Nothing

Honeywell RTH3100c Wiring Question [ 1 Answers ]

I have a Goodman 5 ton 13 seer heat pump. We have a pre-existing heating unit (electric) that is to be used for just Emergency heat. I connected all the wires, but there was a question that came up. The manual said that if the old thermostat had w1, w2 and why wires, I need to contact a heating...

Wire Honeywell Humidifier [ 2 Answers ]

I have an HE360A humidifier, an h8908b manual humidistat and a two stage Trane Furnace. The Furnace already has a 120 to 24v transformer wired to the furmace, which is how the old April air humidifier was wired. There are two yellow wires coming out of the water inlet solenoid on the...

2 Wire White-Rogers with no wallplate wire question [ 2 Answers ]

Hi there. I want to replace my current White-Rogers 1E56W309 thermostat with a new Honeywell RTH7500D. The problem is that the tools that installed my high efficiency furnace didn't install the wall plate with my thermostat (it was a new house and the builder contracted these guys). Instead,...

Installing Honeywell RTH230B, what to do with blue (B) Wire [ 0 Answers ]

I am trying to install of Honeywell RTH230B thermostat. I removed the old Lux mercury thermostat and their were five wires Rh, W, Y, G, and B (blue). The thermostat has place for all of the wires except the B(blue) wire. Do I need a different thermostat or can the B wire be put in the Rc space...


View more questions Search