Old Jun 9, 2005, 07:43 AM
tekki
New Member
tekki is offline
 
Join Date: Jun 2005
Posts: 4
tekki See this member's comment history on his/her Profile page.
Controlling HVAC with X10 Relay

I would like to turn off my AC when the Patio door and or windows are left open for 3 min. I am currently using Homeseer along with the Gemini Napco Plugin. I can detect the opening and closing of the door and window zones and then create an event to trigger an X10 command after 3 minutes to a Power Flash (which is an x10 relay). My main question is how to properly wire the Power Flash Relay to my Thermostat wires at the HVAC system so that I can make or break a connection that controls the AC withouth damaging my HVAC System.

Reply With Quote
 
     

Answers
 
 
Old Jun 9, 2005, 08:13 AM   #2  
Dogs Expert
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,609
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
Most A/C units have a pair of 24 V AC wires running from the furnace terminal block to the compressor relay coil. Usually the terminals are labeled Y and B or C, using yellow wire from the thermostat and blue from the transformer. You could tie in a NCC relay anywhere to break the circuit on command. If you tie it into the red wire between the furnace and thermostat, it would also shut off the furnace when the door is left open.
  Reply With Quote
 
     
 
 
Old Jun 9, 2005, 08:26 AM   #3  
New Member
tekki is offline
 
Join Date: Jun 2005
Posts: 4
tekki See this member's comment history on his/her Profile page.
Thanks for the response. Using which method will provide constant power to the thermostat so that by using this relay to power off the furnace it will not cause power to be lost at the thermostat? Also, I have noticed that when the thermostat reaches the desired temperature the fan continues to operate for a short period of time and then shuts off. By placing a relay to control the HVAC will the blower operate the same way?
  Reply With Quote
 
     
 
 
Old Jun 9, 2005, 09:13 AM   #4  
Dogs Expert
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,609
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
Usually there is a yellow wire running from the Y terminal at the thermostat to the Y terminal at the furnace. Break that connection, it is the same as turning the A/C off at the thermostat. The fan controls will still function as needed.
  Reply With Quote
 
     
 
 
Old Jun 9, 2005, 09:18 AM   #5  
New Member
tekki is offline
 
Join Date: Jun 2005
Posts: 4
tekki See this member's comment history on his/her Profile page.
Thanks again. I will give it a try tonight
  Reply With Quote
 
     
 
 
Old Jun 13, 2005, 06:03 AM   #6  
New Member
tekki is offline
 
Join Date: Jun 2005
Posts: 4
tekki See this member's comment history on his/her Profile page.
I ended up breaking the red wire connection. The system works fantastic, If the zones are open for more than 3 minutes it kicks off the A/C and the fan will continue to run for approx 60 sec like it normally should. If the zones are closed for 3 minutes the system kicks back on. This turned out to be a much cheaper solution then buying an X10 Thermostat when I was only looking for this particular function.

Thanks again!
  Reply With Quote
 
     


Thread Tools
Display Modes

 
Similar Sponsors

Similar Threads
Question Asker Forum Answers Last Post
Controlling interest shayshay Small Business 4 Aug 5, 2006 11:07 AM
Controlling the air-waves jstnvme Music 2 Jan 19, 2006 05:24 PM
HVAC Transformer? Please help! nynks2351 Heating & Air Conditioning 3 Nov 14, 2005 09:46 AM
Any hints for controlling a control freak? tiggerella Workplace Relationships 0 May 18, 2005 07:39 PM
controlling frames bevered Internet & the Web 0 Apr 20, 2004 07:44 AM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 04:38 AM.