    Condenser Shuts Off
    Looking through the threads, I haven't found anything quite like what I'm experiencing. So if there's already a post out there on this topic, I apologize. I have a dual zone heat pump system, and both units are approximately 14 years old. On a normal summer day (70s to 80s) my air works fine. However, when it gets into the high 90s (usually accompanied by high humidity), the condenser that feeds the upstairs will just shut off for hours at a time. The air handler will still run, but all I get is warm air. Once the day starts to cool off toward the evening, the condenser will start back up, and everything is fine afterwards. I just had the unit serviced for its 6 month, and a leak test was performed also, but no problems were found. 1lb, which I know isn't much, of R-22 was added as well.. . And of course, when someone comes out to troubleshoot the problem, no one can find the culprit. Any suggestions would be greatly appreciated!
    letmetellu's Avatar
    letmetellu Posts: 3,151, Reputation: 317
    Ultra Member
     
    #2

    Aug 30, 2006, 08:54 PM
    This could be the cause of your problem, it sounds like heat is a possible problem and one of the things that heat does is make the compressor over heat and it will not come back on till is has cooled. Two things can make the compressor over heat one is an over charge of freon, the other is not enough air going through the fins on the outside condensing unit. First turn off the units power and then use a water hose and wash all of the coil on the outside unit. Let dry for a while and then restart the unit.. . Hope this is the problem.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Condenser fan not running [ 5 Answers ]

I have a 25 year old Carrier (Model 28GS) A/C. It has been working fine until today. The condenser fan (outdoors) doesn't turn on, but I do hear the hum of the compressor. I believe the fan should be running all the time. I'm assuming the compressor is operating OK, even though it's not that...

Condenser problems! [ 5 Answers ]

I purchased a used condenser unit from a reputable hvac dealer/installer last year, but only this year got a chance to install. Everything as far as I know was hooked up correctly, but when the thermostat is turned to a/c the contactor engages but absolutely nothing from the condenser. The blower...

Fan in outside condenser not working [ 0 Answers ]

I live in a 20 year old condo in New England. I have central air. I turned on the air for the 1st time this season. I can hear the condenser outside my building running or at least there is noise coming from it. However, the fan in the condenser is not working nor am I getting any cold air into the...

Condenser Fan Not Working [ 2 Answers ]

Central A/C system turns on using thermostat however, no air blows out of vents. Inspected condenser fan and noticed it was not running. While unit was on, I turned fan by hand and it started to rotate on its own. After an hour of normal operation, the condenser fan stopped again. Could this mean...

Outside condenser fan not working [ 2 Answers ]

Outside unit condenser fan not running. Compressor seems working OK. I followed some advice to have run capacitor replaced but still the same. I also found there is a small noise inside the unit even we don't run that air conditioner. There is no sign we have a burned wire and fan motor likes...


View more questions Search