Question
 
 
#1  
Old Dec 18, 2008, 04:58 PM
chim9656
New Member
chim9656 is offline
 
Join Date: Dec 2008
Posts: 6
chim9656 See this member's comment history on his/her Profile page.
Concord 90 plus high efficiency furnace

For past few days home temperature drops down approx 6-7C degrees at night so I checked the furnace which gives me sometimes (6) LED signals other times (3) LED signals. I followed the back panel instructions also drain out water from tube connecting to motor and restart, however each time it lasts for an hour or so and dies out again for next cycle. Please advise..Thx

Reply With Quote
 
     

Answers
 
 
Old Dec 18, 2008, 05:26 PM   #2  
Ultra Member
wmproop is offline
 
Join Date: Jun 2007
Posts: 1,954
wmproop See this member's comment history on his/her Profile page.
clear out the line thats stopped up,,the condensation is suppose to be draining away and out,,,then it won`t build up in your system

Comments on this post
pattilaw : This worked, we drained the tube and the furnace came back on. Although, the tube keeps filling up and then it shuts off again, we have to figure out a way to make it keep draining.
  Reply With Quote
 
     
 
 
Old Dec 18, 2008, 05:40 PM   #3  
Ultra Member
KC13 is offline
 
KC13's Avatar
 
Join Date: Aug 2007
Location: Cincinnati, Ohio
Posts: 2,046
KC13 See this member's comment history on his/her Profile page.
And don't try to devise a clever system whereby you use the furnace condensate to irrigate your indoor garden...it won't be pretty...
  Reply With Quote
 
     
 
 
Old Dec 18, 2008, 06:23 PM   #4  
New Member
chim9656 is offline
 
Join Date: Dec 2008
Posts: 6
chim9656 See this member's comment history on his/her Profile page.
How do I take the water or codensation out? isn't it suppose to evaporate by itself. I have been draining out manually by removing yellow nipples, however it builds up up again? Somebody ......Please help
  Reply With Quote
 
     
 
 
Old Dec 18, 2008, 06:28 PM   #5  
Ultra Member
acetc is offline
 
Join Date: Jul 2007
Location: So. Cal.
Posts: 1,006
acetc See this member's comment history on his/her Profile page.
you need to connect a drain line to it so that it can constantly drain while in operation.
  Reply With Quote
 
     
 
 
Old Dec 18, 2008, 06:29 PM   #6  
New Member
chim9656 is offline
 
Join Date: Dec 2008
Posts: 6
chim9656 See this member's comment history on his/her Profile page.
The transparent tube which connects to the pressure switch also codensated and LED signal 3 flashes which reads as," Pressure switch open, should be closed"
  Reply With Quote
 
     
 
 
Old Dec 18, 2008, 06:31 PM   #7  
Ultra Member
wmproop is offline
 
Join Date: Jun 2007
Posts: 1,954
wmproop See this member's comment history on his/her Profile page.
whoever installed your furnace was suppose to install a drain system so the condensation would drain out either into a floor drain or into a condensation pump that would then pump the water away,,,if you don`t have this you need a hvac tech to take care of the prob. that the installer didn`t do right
  Reply With Quote
 
     
 
 
Old Dec 18, 2008, 06:32 PM   #8  
Ultra Member
wmproop is offline
 
Join Date: Jun 2007
Posts: 1,954
wmproop See this member's comment history on his/her Profile page.
how long has this been going on>??
  Reply With Quote
 
     
 
 
Old Dec 18, 2008, 06:34 PM   #9  
New Member
chim9656 is offline
 
Join Date: Dec 2008
Posts: 6
chim9656 See this member's comment history on his/her Profile page.
Past 6 years I never had connected any additional drain. Do I need one now? My understanding is that the condensation is blown out by vent motor air pressure...out of the house...Please correct if I'm wrong
  Reply With Quote
 
     
 
 
Old Dec 18, 2008, 06:36 PM   #10  
New Member
chim9656 is offline
 
Join Date: Dec 2008
Posts: 6
chim9656 See this member's comment history on his/her Profile page.
Had this prolm last yr. I just turned the main gas line off and couple times and was ok since then.....nostarted again about 3-4 days ago
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
Concord 90 Plus High Efficiency Heater
(4 replies)
Concord 90 Plus High Efficiency Furnace
(2 replies)