Ask Experts Questions for FREE Help !
Ask
    Suginoman's Avatar
    Suginoman Posts: 1, Reputation: 1
    New Member
     
    #1

    Apr 26, 2007, 09:54 PM
    Coleman Presidential electric furnace
    The blower fan on my electric furnace will not shut off without tripping the main breaker switch. It is an older furnace that had not been used all too often as I generally use a wood/coal stove for heating, but had been operating properly when I have used it. The last time it was used , the thermostat was set for 70 degrees but when I noticed, it was at 75 and the furnace was still running. The only way I could shut it off was by the main breaker
    JackT's Avatar
    JackT Posts: 260, Reputation: 19
    Full Member
     
    #2

    Apr 27, 2007, 02:58 AM
    I'm a little confused, you stated the blower keeps running but also said the temperature is increasing so I assume the heat is also staying on. You could have several things that will cause this. Remove the wire off the R or W terminal on your thermostat, if the furnace goes off, you most likely have a bad thermostat. If after removing the wire on W the furnace continues to heat, you probably have a bad relay or defective circuit board. When the heating elements are "on" the blower should never go off. Please respond back if you have anymore questions or updated information.
    dorothy780's Avatar
    dorothy780 Posts: 3, Reputation: 1
    New Member
     
    #3

    Jan 8, 2010, 10:18 AM
    Serial n0. 129130768 in front of the blower is a switch that has 3different settings can you tell what it is for

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Electric Coleman Mobile home furnace [ 6 Answers ]

The blower fan keeps running and will stop until the breaker is shut off for a while. It may run fine through its complete cycles for a day or two, but will do it again! The furnace hasn't been used for about 4 years. What needs fixed or replaced, and where do I find these parts? The trailer was...

Coleman electric furnace fan runs only in manual [ 2 Answers ]

I have a mobile with a forced air Coleman electric heat. The fan will not run in the auto setting (switch by motor in cabinet) but the element will heat up. In manual the fan runs constantly and heat comes on with the thermostat. The heating company recently replaced the sequencers and said we...

Coleman Furnace [ 1 Answers ]

I have a Coleman Furnace in my mobil home and it keeps shutting off and won't hold a temperature. I have had a furnace company out and they replaced a gas valve but it did not help. To get the furnace to start back up I have to turn the thermostat off and then back on. It will run for a while the I...

Coleman Furnace [ 2 Answers ]

Our furnace is kicking on and off. Then it'll kick, but not go further to turn on the blower and heat? Do you think control issue or booster assembly>

Coleman Furnace [ 1 Answers ]

Burner will not stay light. Fan comes on, ign. Box activates, ign. Comes on, gas sol. Opens, Flame for 2-3 sec. ign. Box de-activates and drops gas sol. Ignitor after hot reads 40 ohms, cooling off as high as 170 ohm. Replaced: Ignitor box Gas sol. Blower PC Furnace was flooded with...