#1  
Old Jun 14, 2007, 07:58 PM
gander2655
New Member
gander2655 is offline
 
Join Date: Jun 2007
Posts: 4
gander2655 See this member's comment history on his/her Profile page.
Central Air blower not working

My central air conditioning blower is not working. Fan on outside unit works but inside fan does not. When I manually turn the fan on at the thermostat it still does not work. What do I need to check?

Reply With Quote
 
     

Answers
 
 
Old Jun 14, 2007, 08:39 PM   #2  
Ultra Member
hvacservicetech_07 is offline
 
hvacservicetech_07's Avatar
 
Join Date: Apr 2007
Location: Effingham, Illinois
Posts: 1,073
hvacservicetech_07 See this member's comment history on his/her Profile page.
Send a message via MSN to hvacservicetech_07
Start by shutting the power off to the furnace and spinning the blower wheel by hand, Does it spin freely? If so, it could just be a capacitor, it also may be the fan relay, post a little more info about your system if you can.
  Reply With Quote
 
     
 
 
Old Jun 15, 2007, 06:37 PM   #3  
New Member
ulbhpy is offline
 
Join Date: Jun 2007
Posts: 6
ulbhpy See this member's comment history on his/her Profile page.
Hi, I have exact same problem. My indoor blower quit working, first it made wierd sounds during start few times and then quit. The capacitor was replaced yesterday and fan started working after about 20-30 secs. We were very happy. We just came back from dinner and it has died again. Should I get the fan relay replaced? What seems to be blowing the capacitor? Thanks for reading and any suggestions.

ulbhpy
  Reply With Quote
 
     
 
 
Old Jun 17, 2007, 05:43 PM   #4  
New Member
gander2655 is offline
 
Join Date: Jun 2007
Posts: 4
gander2655 See this member's comment history on his/her Profile page.
This is a Lennox system about sixteen years old, but was not used a lot until the past five years. It was a vacation home until we moved here. This thing is in the crawl space of the house and is difficult to access. I opened up the panel to see if there was anything obvious and didn't see any loose wires, etc. I saw the relay and capacitor but don't really know how to test them. I don't have a clue as to how to get to the fan. - didn't hear any funny noises prior to it going out - it just stopped blowing.
  Reply With Quote
 
     
 
 
Old Jun 17, 2007, 06:25 PM   #5  
Ultra Member
hvacservicetech_07 is offline
 
hvacservicetech_07's Avatar
 
Join Date: Apr 2007
Location: Effingham, Illinois
Posts: 1,073
hvacservicetech_07 See this member's comment history on his/her Profile page.
Send a message via MSN to hvacservicetech_07
What is the model number? Does the furnace have power, could the breaker be tripped?
  Reply With Quote
 
     
 
 
Old Jun 18, 2007, 04:23 AM   #6  
New Member
gander2655 is offline
 
Join Date: Jun 2007
Posts: 4
gander2655 See this member's comment history on his/her Profile page.
I would have to crawl back under the house to check the model number, which I will do. The power is on - both breakers at the circuit breaker box did not trip. ( the main unit outside is working) Is there possibly a breaker on the unit in the crawl space? I did not see one when I was under there, but, as I said it is difficult to see anything.
  Reply With Quote
 
     
 
 
Old Jun 18, 2007, 09:56 AM   #7  
New Member
bag211 is offline
 
Join Date: Jun 2007
Posts: 1
bag211 See this member's comment history on his/her Profile page.
weird I'm dealing with the same situation. In my case the bearings for the blower (squirrel cage) are shot. The "squirrel cage" should rotate freely if it turns stiffly it may be bearings.
  Reply With Quote
 
     
 
 
Old Jun 18, 2007, 05:39 PM   #8  
Ultra Member
hvacservicetech_07 is offline
 
hvacservicetech_07's Avatar
 
Join Date: Apr 2007
Location: Effingham, Illinois
Posts: 1,073
hvacservicetech_07 See this member's comment history on his/her Profile page.
Send a message via MSN to hvacservicetech_07
Remove the cover from the thermostat, remove the red and green wires, twist them together, does the blower come on? Is this a gas or electric furnace? It would really be helpfull if you could give me a model number.....
  Reply With Quote
 
     
 
 
Old Jun 18, 2007, 07:59 PM   #9  
New Member
gander2655 is offline
 
Join Date: Jun 2007
Posts: 4
gander2655 See this member's comment history on his/her Profile page.
Thanks for your help. I had to call the a.c. guy. It was the blower motor - turned red hot when turned on for a few minutes. Because of the location of the unit it was difficult for me to access the blower - he was able to get to it.
  Reply With Quote
 
     
 
 
Old Jun 18, 2007, 08:16 PM   #10  
Ultra Member
hvacservicetech_07 is offline
 
hvacservicetech_07's Avatar
 
Join Date: Apr 2007
Location: Effingham, Illinois
Posts: 1,073
hvacservicetech_07 See this member's comment history on his/her Profile page.
Send a message via MSN to hvacservicetech_07
Good deal! I'm glad you got everything going....
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
Air Conditioning blower working, not cooling
(6 replies)
central air not working
(5 replies)
Central Heat and Air not blowing air at all
(1 replies)
Blower Fan - Central Air - Bryant - INOP
(4 replies)
Central Air not working...Anything else I can try before calling someone in?
(2 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 03:49 AM.