Cast iron radiators won't heat on 2nd level

HELP!

I am starting my 3rd winter in this house. 1st winter all radiators worked. 2nd winter all radiators worked until mid winter then 2 radiators on the second floor stopped working. This year I turned on the system and non of the radiators on the 2nd floor are working.

I have 7 radiators.

3 on the main floor - these all work great. I bled them until water came out of the valve.
4 on the 2nd floor - bled them. Some of them had the air hissing out at first but after a few seconds the hissing stopped. The valves have been open for 2-3 days and still no water coming out of them.

My boiler is in the basement. It is run by gas. The expansion tank is on top of the boiler. The expansion tank seems to be half full when the system is hot or cold. I would think that it would be emptier when it is cold. But not sure if this is correct.

There is a red oblong shaped item about 10 inches tall and 6 inches wide. This is attached between the boiler and the hot water heater and cold water intake from the main line. I believe this is an auto refill of sorts. I think it uses water from the hot water heater so it doesn't shock the system with cold water. Is this correct?

There is also a pressure relief valve between the boiler and the expansion tank. When you lift this valve water drains out of the system.

There is also a small rectangular box that says "Honeywell" (brand/company name") with a dial that is set at 140. This box is also located between the expansion tank and the boiler.

There is some sort of electrical wire that runs to the largest pipe just above the boiler. I have no clue what that is for.

The gauge above the boiler reads 30 feet and 6 lbs per square inch. I have read several post saying that the psi needs to be at least 12. But I am unable to increase this. How do I increase the psi. Most post I read say to use the relief valve to let water in. I don't seem to have such a valve. The one on top of the red oblong thing doesn't seem to do anything and the other just lets water out.

This is what I have tried. I first tried bleeding all the radiators but the second floor radiators won't bleed out. Today I shut off all the radiators but 2 on the second floor. Thinking I could force all the hot water just to these 2 radiators. Nothing. I did notice that the hot water isn't even attempting to go up the pipes. When I am in the basement and follow the pipes you can feel where the hot water meets the cold.

So I need help.

How do I increase the pressure in my system? Is there just not enough water in it? Maybe my auto refill is not letting water in. How do I know if the auto refill is working?

I need help. It is very cold in my house and it will be a long winter if I can't get this up and running! I am very confused and am getting very frustrated.

Thanks!

Duchess Lana

Reply With Quote
 
     

Answers
 
 
Old Oct 14, 2009, 02:37 PM   #2  
Heating & Air Conditioning Expert
hvac1000 is offline
 
hvac1000's Avatar
 
Join Date: Aug 2005
Location: Ohio
Posts: 11,329
hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.
The reason the second floor radiators will not bleed is because you do not have enough altitude/pressure in the boiler. You increase the pressure by adjusting the automatic water feed valve/pressure reducing valve. 12 pounds pressure is usually about right but sometimes it will take a pound or 2 more depending upon the actual height of the structure.

Go to this site for all the info you will need on boilers.

Guide to Automatic & Manual Water Feeder Valves for Hot Water & Steam Boilers
  Reply With Quote
 
     
 
 
Old Oct 14, 2009, 03:53 PM   #3  
New Member
duchesslana is offline
 
Join Date: Oct 2009
Posts: 8
duchesslana See this member's comment history on his/her Profile page.
Ok. I don't understand how to let the water in to increase the pressure. All the valves are open but nothing seems to be happening. The red oblong thing is a Bell & Gossett #500. There is a valve on top that I have lifted and turned. There is also a valve on the side that I also have turned. Nothing seems to happen.

Now what?
  Reply With Quote
 
     
 
 
Old Oct 14, 2009, 04:05 PM   #4  
Ultra Member
mygirlsdad77 is offline
 
Join Date: Aug 2008
Posts: 2,666
mygirlsdad77 See this member's comment history on his/her Profile page.mygirlsdad77 See this member's comment history on his/her Profile page.
Can you post some pictures of the items you are talking about, and please label them what you call them.. Also, how many thermostats do you have in the home? how many pumps on boiler system(or do you have zone valves?). I agree with hvac1000, 6psi at boiler is to low of pressure to let upstairs registers work correctly. There are ways to increase pressure without the pressure reducing valve, but i wouldnt suggest anyone but a pro doing this. Hope you can show us some pics, and we may be able to help you out with this.
  Reply With Quote
 
     
 
 
Old Oct 14, 2009, 06:21 PM   #5  
New Member
duchesslana is offline
 
Join Date: Oct 2009
Posts: 8
duchesslana See this member's comment history on his/her Profile page.
Pictures of my unit are attached.
Attached Images
     
  Reply With Quote
 
     
 
 
Old Oct 14, 2009, 06:40 PM   #6  
Ultra Member
mygirlsdad77 is offline
 
Join Date: Aug 2008
Posts: 2,666
mygirlsdad77 See this member's comment history on his/her Profile page.mygirlsdad77 See this member's comment history on his/her Profile page.
ouch,,cant help you with this one, i can only suggest upgrading to a newer boiler with recirc pumps. I try to stick to a rule of thumb that i wont give repair advice on items that are older than me(and this is way older than me,, im guessing its more like the age of my great grandfather..lol). Hope one of the other boiler pros can give you better advice on curing your problem with your current boiler. Sorry i couldnt help, i just dont have the experience with this type of system(I beleive you have a gravity system). Take care, and please let me know how you make out. Lee.
  Reply With Quote
 
     
 
 
Old Oct 14, 2009, 06:45 PM   #7  
Ultra Member
mygirlsdad77 is offline
 
Join Date: Aug 2008
Posts: 2,666
mygirlsdad77 See this member's comment history on his/her Profile page.mygirlsdad77 See this member's comment history on his/her Profile page.
hvac1000,,,Im really curious about your thoughts on this boiler,,,ive seen them before, but my only experiecne with them was breaking them down, and hauling them to the dump. Can you help me learn a bit about them, so i can try to service them in the future.
  Reply With Quote
 
     
 
 
Old Oct 14, 2009, 06:51 PM   #8  
New Member
duchesslana is offline
 
Join Date: Oct 2009
Posts: 8
duchesslana See this member's comment history on his/her Profile page.
Thanks for the attempted help mygirlsdad77. Maybe we will both learn something about this unit.

It definitely is a gravity system. There is no circulation pump. The boiler itself works very well. Heats quickly.

I did have someone come in a year ago to quote me on replacing it. But the price was just way to high. Unless of course I went with forced air. Don't want forced air - especially with my high allergy problems.

Thanks again.

Anyone else have any ideas on how to increase my PSI?
  Reply With Quote
 
     
 
 
Old Oct 14, 2009, 08:19 PM   #9  
Heating & Air Conditioning Expert
hvac1000 is offline
 
hvac1000's Avatar
 
Join Date: Aug 2005
Location: Ohio
Posts: 11,329
hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.
Post the exact part numbers off the tag on the Red valve in the picture. Tag looks to be at bottom of valve.
  Reply With Quote
 
     
 
 
Old Oct 14, 2009, 08:27 PM   #10  
New Member
duchesslana is offline
 
Join Date: Oct 2009
Posts: 8
duchesslana See this member's comment history on his/her Profile page.
the tag reads

#500
Relief valve set at 30lbs
Reducing valve 12lbs
Manufactured by Bell & Gossett Company
Morton Grove, IL
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login



Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes
Ask your question or search...



Similar Threads
cast iron to pvc
(1 replies)
Can I cut a cast iron tee wye after the hub?
(3 replies)
cast iron vertical from cast iron horizontal can be pvc?
(2 replies)
cutting through cast iron How is it possible to cut through a cast iron soil pipe
(3 replies)