    My carrier thermostat was working, but then fan ran continuous. Checked thermostat, not lit.
    Book says internal power source, not battery, could this have given up, even with power still on? Is this renewable or do I need a new thermostat? It is 10 years old.
    Thanks
    labman's Avatar
    labman Posts: 10,580, Reputation: 551
    Uber Member
     
    #2

    Oct 13, 2006, 04:39 AM
    Unfortunately likely it is the relay for the fan. A cheap little part located on an expensive circuit board and prone to failure. The thermostat would be much cheaper to replace. Try pulling the green wire off either the circuit board or thermostat, and see if the fan still runs. If so, the problem is in the furnace.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Carrier furnace [ 2 Answers ]

Blower runs, furnace won't ignite. ( pilot light IS WORKING) 1. filter was cleaned 2. thermostat reprogrammed . Is there anything we can do beafore calling service?

Carrier vs. Frigidaire? [ 2 Answers ]

I have a few quotes from some a/c companies to put a new system in my house because my current system is 20+ years old and is working against me at this point. I have propane heat and want to get electric because of the rising gas prices. The total sq. footage is approx 2600... the two estimates...

Carrier Furnace [ 4 Answers ]

I am looking at furnace for a friend. The furnace will come on with that small fan and the pilot will light. However, the burner will not catch. This unit has a igniter I suspect that the igniter is bad. Is there any way to test it?


View more questions Search