    Can I connect a honeywell rth2300 thermostat with only 2 wires coming out of the wall
    I am trying to install a honeywell rth2300 programmable thermostat, but there are only 2 wires coming out of the wall and attaching to the old school thermostat. Will I be able to install this thermostat or do I need a different model? I am connecting only to a furnace, no ac. Thanks Po
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #2

    Nov 15, 2010, 03:28 PM
    There was a similar post a day or two ago. Heta only; Red goes to RH and White goes to White. From the manual I saw, you need to remove the red jumper that is between RC and RH. Should work. Hope this helps. Brian
    cvenable's Avatar
    cvenable Posts: 2, Reputation: 1
    New Member
     
    #3

    Nov 15, 2010, 07:36 PM
    Hi Brian,
    I spoke with Honeywell help desk, but they weren't able to assist since the old thermostat didn't have any letter designations for the terminals that the white and black wires from the wall were attached to. They suggested I trace the wires back to the furnace. That I did with the help of the furnace installation manual. A bit more investigation and I determined that the black wire was the red wire and white wire was in fact white. All hooked up and working fine.
    Thanks so much for your help.
    Cindy
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #4

    Nov 15, 2010, 09:24 PM
    Comment on cvenable's post
    Hey you're good! Thanks for your comment. You can "tip" me by clicking yes! -is this helpful. Glad we could help.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

W o g are c why wires thermostat = rth2300 [ 3 Answers ]

My old thermostat has the wogrcy and when I connect the new model rth300, the ac doen't run

How do I connect my honeywell rth2300 thermostat and make it stop when right temp. [ 12 Answers ]

My honeywell rth2300 has W,G,R,and B, COLORED wires connected, and my old thermostat had a yellow and white cable attached to mercury. To my understanding, digital thermostats don't have mercury, but they will lack connection of wires because there are only 4 coming out of the wall. How do I make...

How do I connect wires from Janitrol to the Honeywell Thermostat [ 1 Answers ]

How do I connect the wires from a Janitrol to the Honeywell RTH7500 Thermostat. I have the following wires: R Red Y Yellow G Green O Orange W2 White E Beige/Pink C Blue Black wire not connected

How to connect wires to a RTH6300B honeywell thermostat [ 2 Answers ]

I only have 2 wires to connect I removed the old wires from the W and R connection And put them on the new one but nothing happens. Any help would be appreciated


View more questions Search