Home > Home & Garden > Heating & Air Conditioning   »   No power after thermostat replaced

 
Question Tools Search this Question Display Modes
Question
 
 
#1  
Old Sep 27, 2005, 04:44 PM
mymechi
New Member
mymechi is offline
 
Join Date: Sep 2005
Posts: 3
mymechi See this member's comment history on his/her Profile page.
Send a message via MSN to mymechi
No power after thermostat replaced

Ok...I know better...but since i was dealing with low voltage...i figured no harm...WRONG! I should of turned off the breaker when replacing my thermostat...enough said. I replaced my thermostat (simple comfort 3001) with a honeywell RTH6300b because the simple comfort display was jittering off and on, but still working. Anyway, when disconnecting the wires i noticed a small spark. DUH!....After replacing it with the honeywell, no power. I mean the display was there, but it has batteries so that's that. But no fan would come on., I then switched back to the old one (no batteries), and nothing. Not even a display. The wires out of the wall are red to R/RH,white to W,yellow to Y,green to G and blue to B. That's how it was connected to the old one as well...(the letters to the codes.) Connecting to the honeywell I did the same except that the blue wire, I was instructed by the manual to tape off because I have gas heat/ac. Not needed. My question is, blown transformer or is there a fuse that might have blown? Also location of both to check. Air handler i know, in the garage up high (oh boy)...but where abouts?
Thanks, chuck

Reply With Quote
 
     

Answers
 
 
Old Sep 27, 2005, 05:41 PM   #2  
labman
Dogs Expert
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,602
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
The first step is to check for 24 volts between the red and blue wire. If it is dead, the transformer may be too unless it is protected by a fuse. The fuse is likely near the transformer, either in line, or on a nearby control board. They are usually in the furnace. Follow the red and blue wires back to it. One little spark shouldn't burn up the transformer. With luck, it is a fuse.
  Reply With Quote
 
     
 
 
Old Sep 27, 2005, 07:10 PM   #3  
mymechi
New Member
mymechi is offline
 
Join Date: Sep 2005
Posts: 3
mymechi See this member's comment history on his/her Profile page.
Send a message via MSN to mymechi
Thanks, I'll try and locate to see if it is indeed a fuse (which i hope) and let you know!
chuck
  Reply With Quote
 
     
 
 
Old Sep 28, 2005, 02:45 PM   #4  
mymechi
New Member
mymechi is offline
 
Join Date: Sep 2005
Posts: 3
mymechi See this member's comment history on his/her Profile page.
Send a message via MSN to mymechi
That was the ticket! Blown 3amp fuse on control board inside air handler.
Thanks "LABMAN"...you r da man! chuck
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
no power to thermostat summerbarbie71 Heating & Air Conditioning 2 Sep 14, 2006 04:35 PM
replaced thermostat - now no hear or a/c! opm8 Heating & Air Conditioning 5 Aug 12, 2006 03:50 PM
Furnace won't stop blowing air - replaced the thermostat SumDuud Heating & Air Conditioning 2 Nov 17, 2005 05:47 AM
no power to thermostat charyaskmehelpdesk Heating & Air Conditioning 13 Aug 6, 2005 06:02 PM
No Power to Thermostat dboeth Heating & Air Conditioning 2 Jul 29, 2005 11:55 AM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 11:43 PM.

Content Relevant URLs by vBSEO 3.0.0 RC6 © 2006, Crawlability, Inc.