Ask Experts Questions for FREE Help !
Ask
    jebeka's Avatar
    jebeka Posts: 2, Reputation: 1
    New Member
     
    #1

    Oct 13, 2011, 09:02 PM
    Burners ignite but Won't stay on
    I have a Tempstar furnace. It is a natural gas furnace and the gas valve and the electrical parts are Honeywell (Gas Valve VR8204M1075, Control Module ST9120C4057, Ignition Module S8600M1005). The furnace is about 10 years old. When I tried to turn it on for the first time this year it would ignite for a bit and then go out and then repeats that cycle. The main burners ignite and the pilot stays on. I changed the pilot mechanism (with the igniter and sensor) and it still does the same thing. I've realized that the first time it turns on after being off a while it'll run for about a minute and then the off/on cycles get progressively more rapid until it just flicks on and shuts off. The filter is brand new and the blower comes on and works fine. It's just the burners keep turning off. Could it be that it's overheating somehow or a sensor thinks it's overheating, like the limit control? Any ideas would be great

Check out some similar questions!

Burners ignite and stay on, blower does not? [ 2 Answers ]

I have a Rheem RRPLB024JK08E outdoor gaspack, 5 months. Old. It locked itself out, red lights indicate high limit open. Put in new high limit switch, no change. After I reset it (kill power) it works fine for about 8 or 10 cycles. Then, draft inducer comes on... burners ignite and stay on, but no...

Furnace burners ignite but won't stay lit on my trane xe78 furnace? [ 0 Answers ]

I have a Trane XE78 furnace and the flames come on for about 5-10 seconds and then shut off. They re-ignite about 10 seconds later, then shut off 5-10 seconds after the 2nd ignition. I believe they flame on one more time, shut off and then never re-ignite and the blower just runs and runs with...

Burners do not ignite [ 1 Answers ]

My gas furnace pilot light will not ignite the burners. Can you help?

Burners will not ignite [ 1 Answers ]

I have a Day/Night forced air heater and the burners will not light. The fan runs but the igniter glow device does not turn red and the gas valve does not open. I have run the on test mode and the igniter glows red but when turned on by the thermostat the igniter does not work. I have checked the...


View more questions Search
 