    Bryant Thermostat Has Intermittent Blank Display
    I have a Bryant Furnace with the Bryant thermostat that came with the unit. This is a non-programmable thermostat and is powered by electric (no battery power). The problem is intermittent but while the furnace is running sometimes there is no display on the thermostat. Pressing the up/down tempature settings do not bring the display back automatically. After a few minutes the display will come back and then it will display HC for a moment and then display the current room tempature.

    I don't want to call a furnace repair man to find out it is a simple fix on my end. Any adivse appreciated.

    The model number of the furnace is CK5BXA030014AAAA

    Lori
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Nov 7, 2007, 04:35 PM
    Sounds like the thermostat coule be bad, Try to reset by turning off the main electric power to your furnace for a few minutes then turn back on. If it does not reset it is probably a defective stst.
    acetc's Avatar
    acetc Posts: 1,004, Reputation: 79
    Ultra Member
     
    #3

    Nov 7, 2007, 04:58 PM
    If this is a new thermostat then it may be that there is no common wire to the thermostat, this problem would only show up in the heating mode if this is the problem, look at the wires on the back of the thermostat, you should have at least five wires, one of these would be a common and connected to the "C" terminal. Good luck, Mike
    T-Top's Avatar
    T-Top Posts: 1,871, Reputation: 100
    Ultra Member
     
    #4

    Nov 7, 2007, 07:05 PM
    If a limit switch opens in the heating mode it kills 24volts going to the system(making the T-stat go blank) The blower will be the only thing on at that time. The way you describe it, it sounds like the main limit is opening up and resetting after it cools off. Check for restricted air flow-- Dirty return air filter, dirty or restricted blower wheel inside furnace, make sure all your supply vents are open not restricting the air flow. Good luck.
    RubberMan's Avatar
    RubberMan Posts: 1, Reputation: 1
    New Member
     
    #5

    Jan 5, 2010, 07:41 PM
    T-Top, Thanks for the description above, it save us $550. Our Bryant Thermostat display had been going blank, called service and they recommended replacing the unit. Opened all the register vents, adjusted the filter and problem is solved. Thanks again.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Honeywell T8001 Thermostat - Blank Display [ 1 Answers ]

Kids while playing in the backyard were banging against the outside compressor unit and I found later that the display on the thermostat is now blank. So I can not switch on heating or air conditioning. Since my house has two units one for upstairs and one for downstairs, I tested by swapping the...

Thermostat display is blank [ 6 Answers ]

I have a Honeywell programmable thermostat and the display is blank. We had a bad storm and the power went out. I have checked the breaker and reset it. The blower will come on when I switch it to ON, but nothing else works. Can someone help?

Blank Thermostat [ 6 Answers ]

Hi Guys, I had the A/C unit running fine today... then all of a sudden my thermostat went blank... It was raining on and off today here in Plano, Texas... It is a Carrier A/C furnace unit, controlled by a Honeywell Thermostat... This thermostat gets its power from the unit itself... In the...

Thermistat display goes blank and comes back intermittently. [ 2 Answers ]

I have a Bryant (Carrier) programmable thermidstat that has worked without problem for 2+ years. The problem is that the LCD and backlight goes out intermittently during the time the system is not running. I have yet to determine the exact sequence of when this happens but without intervention the...


View more questions Search