    Bryant Plus 80 Error code 33
    Hello! I'm new on here so bear with me. I found a similuar post on the Bryant 80 but I believe I have a different model... not sure how much that matters. The only model number I could find on the unit was CK5AXA036017AAAA

    The Error code is 33 Limit or flame roll out switch is open. The furnace seems to be working but we haven't had to use it much yet.

    Any ideas on what I need to look at or does someone have a PDF manual they can post for me?

    Thank you!
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Oct 15, 2008, 04:02 AM
    If the flame roll out switch is open usually the furnace will not fire up but the blower may stay on.

    If limit switch is open longer than 3 minutes code changes to code NO. 13
    Check for:
    a)Blower motor failure
    b)motor start capacitor
    c)open flame rollout switch and or reset if possible
    d)inadequate combustion air supply (flame rollout switch only)
    e)dirty air filter
    f)defective limit switch or connections
    rmtz's Avatar
    rmtz Posts: 2, Reputation: 1
    New Member
     
    #3

    Dec 9, 2012, 09:59 AM
    Where is the capicator located and the rollout swicth?
    rmtz's Avatar
    rmtz Posts: 2, Reputation: 1
    New Member
     
    #4

    Dec 9, 2012, 10:00 AM
    Where is the blower capacitor and rollout switn located on a bryant 383K

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Bryant 330AAV Code 34.every now and then. [ 2 Answers ]

Wanted to know if anyone could help me troubleshoot this problem.. This furnace will not fire up (every now and then), basically what happens is the igniter lights up, but will shut down after 5 seconds or so. It will do this three times until it goes into lock down, code 34 flashes. I reset...

Bryant Plus 80 Code 33 [ 10 Answers ]

I have a Bryant Plus 80 that is throwing a error of 33 (limit or flame roll out switch is open). The last time this happened was because the hot surface igniter was broken (frequent problem as my furnace has a tendency to short-cycle). I had picked up a couple extra ones so I had them on hand to...

Still have error code on Bryant gaspac 8 flashes [ 6 Answers ]

For Northernheat Still getting code of 8 led flashes. Have checked the flame sensor not cracked or touching anything and is in the flame. The only time that it seems to happen is when the temp gets colder like 32/34 after being 38/40. The LED error code states Internal control fault ...

Code 41 on Bryant air handler [ 6 Answers ]

Equipment: Bryant Variable Spd 4-Way Multipoise Furnace Model 315AAV060110 package with Bryant Condensing Unit Mod 38HDC060-321. Unit in Florida and issue with cooling operation. Problem start: Odor elec burn at registers. Powered off unit and called repair. Tech did shallow/sloppy diagnostic...

Bryant 310AAV code 23 [ 8 Answers ]

I found your forum after having some issues with my furnace. Age is unknown because I rent and my landlords are out of town. When I went to turn the furnace on tonight, nothing happened. House temp registering 68-69 at thermostat, furnace doesn't kick on when adjusted to 72. Fan will turn...