Ask Experts Questions for FREE Help !
Ask
    Jay.Tutka's Avatar
    Jay.Tutka Posts: 1, Reputation: 1
    New Member
     
    #1

    Oct 1, 2010, 10:18 AM
    Bryant 352MAV and error code 12
    I have the Bryant 352MAV 2-stage furnace that is giving me problems:
    When the thermostat is set below the target temperature i.e. 19C/68F the LED code indicator (on the logic board) is steady ON, once the target temperature is set i.e. 24C/78F , the inductor motor comes on for perhaps 15 sec, then it cots out, then the blower motor kicks in for about 30-45 sec, then the HSI starts glowing and soon after there is a gas ignition. And then it all stops! The gas cuts out, the blower motor stops and the LED code indicator flashes 12 (one short and two long), after a short while the whole process repeats, over and over again.
    Any suggestion on how to get the heat going again is much appreciated.

Check out some similar questions!

Bryant Plus 80 Error code 33 [ 3 Answers ]

Hello! I'm new on here so bear with me. I found a similuar post on the Bryant 80 but I believe I have a different model... not sure how much that matters. The only model number I could find on the unit was CK5AXA036017AAAA The Error code is 33 Limit or flame roll out switch is open. The furnace...

Bryant 395cav error code 31 [ 9 Answers ]

I have a Bryant CAV395024070 furnace that's taking a code 31. When I run a component test, the inducer motor comes on, sometimes for only a second, sometimes for the proper amount of time, sometimes not at all. The remainder of the components all go through the test no matter what the inducer motor...

Bryant 352MAV Code 32 [ 6 Answers ]

Am having a problem with my Bryant 352MAV furnace. Intermittently, the furnace will fail to "run" and the status LED flashes a code 32. I did some troubleshooting on this a year ago and things seemed to be fine but now it's acting up again. Originally I disconnected all of the small diameter...

Bryant 352MAV and error code 32 [ 49 Answers ]

Our furnace worked last night but this AM it didn't. It's a 3 year old Bryant 352MAV, installed horizontally. It's giving error 32. I've spent much of the day working with it. I'm more than handy but don't really know much about hvac. I found that the idiots that installed it (and who are now...

Bryant plus 80 error code 31 [ 1 Answers ]

Bryant Plus 80 furnace - Error code 31 What are the corrective measures to put this furnace back to producing heat? There is power, the fan works but there is no heat. We lost power recently but it worked after that. Last evening there were high winds which were indicated on the code...