Home > Home & Garden > Heating & Air Conditioning   »   Blower runs on "ON", but not on "Auto"

 
Thread Tools Search this Thread Display Modes
Question
 
 
#1  
Old Jan 17, 2007, 09:12 AM
seminole
New Member
seminole is offline
 
Join Date: Jan 2007
Posts: 2
seminole See this member's comment history on his/her Profile page.
Blower runs on "ON", but not on "Auto"

Hello All,
I have a Goodman COMBINATION HEATING AND COOLING OUTDOOR UNITS PG/PGX SERIES (100K BTU). It failed to warm the space. The fan would not run on “ON” or “Auto” mode. Upon investigating, there is no power to the unit due to 25 amps fuses blown. Replaced with new fuses. Power was supplied to the unit, fan can turn on manually (“ON” mode).
When the thermostat was in Heat and Auto mode, the temperature set at 80F. The furnace ignited, felt a breeze of warm air for 3-4 minutes, but the blower was not kicked in to deliver the heat. After 3-4 minutes, the furnace shut down. Reset the thermostat (heat OFF), set Heat and Auto. This time, it was NO HEAT and NO FAN

According to manual:
SEQUENCE OF OPERATION
1. Thermostat calls for heat.
2. Combustion motor is energized, combustion motor interlock is made.
3. Ignition spark is energized.
4. Pilot valve opens and pilot burner lights
5. Sensor proves pilot flame.
6. Ignition spark de-energized.
7. The main gas valve is energized.
8. Pilot flame lights the main burners.
9. Thermostat is satisfied and opens. The main and pilot valves are de-energized, shutting down main and pilot flames.

Here is the wiring instruction:
LEAD -> THERMOSTAT
White -> W (Heat)
Green -> G (Fan)
Yellow -> Y (Cool)
Red R -> (24V.)
Orange -> Y1 Only when economizer is utilized
Pink -> Y2" (not available)

Can anyone please help to troubleshoot this problem? Any inputs are greatly appreciated.
Thanks, Seminole

Reply With Quote
 
     

Answers
 
 
Old Jan 17, 2007, 04:02 PM   #2  
Ultra Member
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,380
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
Sounds like the circuit board is bad, since the fan relay on the board has failed, the blower never turns on, the furnace overheats and the main limit turns everything off when it realizes the furnace is overheated.

Comments on this post
labman agrees: Happened to me. $300 for a new board to replace a fifty cent relay.
  Reply With Quote
 
     
 
 
Old Jan 18, 2007, 07:00 AM   #3  
New Member
seminole is offline
 
Join Date: Jan 2007
Posts: 2
seminole See this member's comment history on his/her Profile page.
Quote:
Originally Posted by seminole
Hello All,
I have a Goodman COMBINATION HEATING AND COOLING OUTDOOR UNITS PG/PGX SERIES (100K BTU). It failed to warm the space. The fan would not run on “ON” or “Auto” mode. Upon investigating, there is no power to the unit due to 25 amps fuses blown. Replaced with new fuses. Power was supplied to the unit, fan can turn on manually (“ON” mode).
When the thermostat was in Heat and Auto mode, the temperature set at 80F. The furnace ignited, felt a breeze of warm air for 3-4 minutes, but the blower was not kicked in to deliver the heat. After 3-4 minutes, the furnace shut down. Reset the thermostat (heat OFF), set Heat and Auto. This time, it was NO HEAT and NO FAN

According to manual:
SEQUENCE OF OPERATION
1. Thermostat calls for heat.
2. Combustion motor is energized, combustion motor interlock is made.
3. Ignition spark is energized.
4. Pilot valve opens and pilot burner lights
5. Sensor proves pilot flame.
6. Ignition spark de-energized.
7. The main gas valve is energized.
8. Pilot flame lights the main burners.
9. Thermostat is satisfied and opens. The main and pilot valves are de-energized, shutting down main and pilot flames.

Here is the wiring instruction:
LEAD -> THERMOSTAT
White -> W (Heat)
Green -> G (Fan)
Yellow -> Y (Cool)
Red R -> (24V.)
Orange -> Y1 Only when economizer is utilized
Pink -> Y2" (not available)

Can anyone please help to troubleshoot this problem? Any inputs are greatly appreciated.
Thanks, Seminole
Many thanks to NorthernHeat and Labman. How can I verify the relay is bad? Where do I find a replacement board?
Thanks, Seminole.
  Reply With Quote
 
     
 
 
Old Jan 18, 2007, 02:31 PM   #4  
Ultra Member
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,380
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
When blower is supposed to turn on you don't get 120 volts to the appropriate female stab pin on the board. Good luck finding a board on your own, wholesalers only sell to licensed contractors.
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
pink pill with "watson" and "502" on it
(2 replies)
Fan Blower not working in "ON" or "AUTO" in heat or AC
(4 replies)
Heater blows cold when "On", not at all on "Auto"
(1 replies)
The blower doesn't start on "Auto"
(10 replies)