Ask Experts Questions for FREE Help!
  Advanced
Register  |  Log in  
   Ask    
 Answer  
  Help  

Ask QuestionsprogressAnswer QuestionsprogressBuild ReputationprogressBecome an Expert
 
Free Answers in 3 Easy Steps

Register Now
3 Steps

At Ask Me Help Desk you can ask questions in any topic and have them answered for free by our experts. To ask questions or participate in answering them you must register for a free account. By registering you will be able to:
  • Get free answers from experts in any of our 300+ topics.
  • Accept money for answers that you provide.
  • Communicate privately with other members (PM).
  • See fewer ads.

Home > Home & Garden > Heating & Air Conditioning   »   Blower runs on "ON", but not on "Auto"

 
Question Tools Search this Question Display Modes
Question
 
 
#1  
Old Jan 17, 2007, 08:12 AM
seminole
New Member
seminole is offline
 
Join Date: Jan 2007
Posts: 2
seminole See this member's comment history on his/her Profile page.
Blower runs on "ON", but not on "Auto"

Hello All,
I have a Goodman COMBINATION HEATING AND COOLING OUTDOOR UNITS PG/PGX SERIES (100K BTU). It failed to warm the space. The fan would not run on “ON” or “Auto” mode. Upon investigating, there is no power to the unit due to 25 amps fuses blown. Replaced with new fuses. Power was supplied to the unit, fan can turn on manually (“ON” mode).
When the thermostat was in Heat and Auto mode, the temperature set at 80F. The furnace ignited, felt a breeze of warm air for 3-4 minutes, but the blower was not kicked in to deliver the heat. After 3-4 minutes, the furnace shut down. Reset the thermostat (heat OFF), set Heat and Auto. This time, it was NO HEAT and NO FAN

According to manual:
SEQUENCE OF OPERATION
1. Thermostat calls for heat.
2. Combustion motor is energized, combustion motor interlock is made.
3. Ignition spark is energized.
4. Pilot valve opens and pilot burner lights
5. Sensor proves pilot flame.
6. Ignition spark de-energized.
7. The main gas valve is energized.
8. Pilot flame lights the main burners.
9. Thermostat is satisfied and opens. The main and pilot valves are de-energized, shutting down main and pilot flames.

Here is the wiring instruction:
LEAD -> THERMOSTAT
White -> W (Heat)
Green -> G (Fan)
Yellow -> Y (Cool)
Red R -> (24V.)
Orange -> Y1 Only when economizer is utilized
Pink -> Y2" (not available)

Can anyone please help to troubleshoot this problem? Any inputs are greatly appreciated.
Thanks, Seminole

Reply With Quote
 
     

Answers
 
 
Old Jan 17, 2007, 03:02 PM   #2  
NorthernHeat
Heating & Air Conditioning Expert
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,355
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
Sounds like the circuit board is bad, since the fan relay on the board has failed, the blower never turns on, the furnace overheats and the main limit turns everything off when it realizes the furnace is overheated.

Comments on this post
labman agrees: Happened to me. $300 for a new board to replace a fifty cent relay.
  Reply With Quote
 
     
 
 
Old Jan 18, 2007, 06:00 AM   #3  
seminole
New Member
seminole is offline
 
Join Date: Jan 2007
Posts: 2
seminole See this member's comment history on his/her Profile page.
Quote:
Originally Posted by seminole
Hello All,
I have a Goodman COMBINATION HEATING AND COOLING OUTDOOR UNITS PG/PGX SERIES (100K BTU). It failed to warm the space. The fan would not run on “ON” or “Auto” mode. Upon investigating, there is no power to the unit due to 25 amps fuses blown. Replaced with new fuses. Power was supplied to the unit, fan can turn on manually (“ON” mode).
When the thermostat was in Heat and Auto mode, the temperature set at 80F. The furnace ignited, felt a breeze of warm air for 3-4 minutes, but the blower was not kicked in to deliver the heat. After 3-4 minutes, the furnace shut down. Reset the thermostat (heat OFF), set Heat and Auto. This time, it was NO HEAT and NO FAN

According to manual:
SEQUENCE OF OPERATION
1. Thermostat calls for heat.
2. Combustion motor is energized, combustion motor interlock is made.
3. Ignition spark is energized.
4. Pilot valve opens and pilot burner lights
5. Sensor proves pilot flame.
6. Ignition spark de-energized.
7. The main gas valve is energized.
8. Pilot flame lights the main burners.
9. Thermostat is satisfied and opens. The main and pilot valves are de-energized, shutting down main and pilot flames.

Here is the wiring instruction:
LEAD -> THERMOSTAT
White -> W (Heat)
Green -> G (Fan)
Yellow -> Y (Cool)
Red R -> (24V.)
Orange -> Y1 Only when economizer is utilized
Pink -> Y2" (not available)

Can anyone please help to troubleshoot this problem? Any inputs are greatly appreciated.
Thanks, Seminole
Many thanks to NorthernHeat and Labman. How can I verify the relay is bad? Where do I find a replacement board?
Thanks, Seminole.
  Reply With Quote
 
     
 
 
Old Jan 18, 2007, 01:31 PM   #4  
NorthernHeat
Heating & Air Conditioning Expert
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,355
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
When blower is supposed to turn on you don't get 120 volts to the appropriate female stab pin on the board. Good luck finding a board on your own, wholesalers only sell to licensed contractors.
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
pink pill with "watson" and "502" on it lwagoner Medications 2 Jan 21, 2008 09:59 PM
Fan Blower not working in "ON" or "AUTO" in heat or AC phelixu Heating & Air Conditioning 4 Aug 4, 2007 08:43 PM
Heater blows cold when "On", not at all on "Auto" mcdisney Heating & Air Conditioning 1 Nov 13, 2006 04:27 PM
The blower doesn't start on "Auto" ravithas Heating & Air Conditioning 10 Nov 29, 2005 09:18 AM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 07:48 PM.

Content Relevant URLs by vBSEO 3.0.0 RC6 © 2006, Crawlability, Inc.