    propmgrjpp's Avatar
    propmgrjpp Posts: 2, Reputation: 1
    New Member
     
    #1

    Jul 27, 2010, 08:56 AM
    Air conditioner not cooling
    A/C not cooling below 80 when outside temp is 98. It is a split system, inside & outside coils clean, unit and ducting in house attic, just had ducting replaced and is insulated well, R30 blown in insulation in attic, return is against roof, 3T for a 1800 sqft brick 30 yr old house. What else to do or check?
    Joshdta's Avatar
    Joshdta Posts: 2,549, Reputation: 45
    Ultra Member
     
    #2

    Jul 27, 2010, 09:17 AM

    Probably nothing. Ac units are only designed to cool 20 degrees below the outdoor temp. so yours when new should get dow to 77 or 78 when it is 98 out. How old is the unit? The older a unit is the less effencant it becomes. Do you have a attic fan in your house to pull heat out of the attic?
    propmgrjpp's Avatar
    propmgrjpp Posts: 2, Reputation: 1
    New Member
     
    #3

    Jul 28, 2010, 08:28 AM
    Quote Originally Posted by Joshdta View Post
    Probally nothing. Ac units are only designed to cool 20 degrees below the outdoor temp. so yours when new should get dow to 77 or 78 when it is 98 out. How old is the unit? The older a unit is the less effencant it becomes. Do you have a attic fan in your house to pull heat out of the attic?
    Unit installed 10-2007 3 Ton split 13 seer system. Just intalled 2 gable fans, there is a roof ridge vent and soffitt vents and a large grill vent at the end of the attic space above the carport that is perpendicular to the house.
    Jeni14's Avatar
    Jeni14 Posts: 9, Reputation: 1
    New Member
     
    #4

    Aug 11, 2010, 08:26 AM

    I'm having the same problem. Sometimes when it's 87 outside, I have my house temp set on 75 and the house is 78 and will run for 12 hours straight. I don't think this is how an A/C unit is designed to run.
    wmproop's Avatar
    wmproop Posts: 3,749, Reputation: 91
    Ultra Member
     
    #5

    Aug 11, 2010, 09:10 AM
    Quote Originally Posted by Jeni14 View Post
    I'm having the same problem. Sometimes when it's 87 outside, I have my house temp set on 75 and the house is 78 and will run for 12 hours straight. I don't think this is how an A/C unit is designed to run.

    You are right, if you are sure the furnace filter is clean, and all units are running ,its about all you can do, but call a local hvac tech to look it over,, 12 hours straight is a lot of electricity to be waisted
    Jeni14's Avatar
    Jeni14 Posts: 9, Reputation: 1
    New Member
     
    #6

    Aug 11, 2010, 09:27 AM

    I agree! It is a brand new unit installed at the end of May. The coil wasn't replaced until early July because no one realized it wasn't compatible, there was a leak in the line from the weld of the new coil and that has been fixed. The filter is only 4 weeks old so probably needs to be replaced, but isn't crazy overdue. Return air is 20 hotter than the air coming out of the vents and the humidity in the house is about 49% so all of that sounds like it's working fine. I'm having someone over tonight to check the TXV valve, but I don't know what to check beyond that. I thought possibly the tonage is too small, maybe? It's a 2.5 ton unit with a 1200 square foot house on the main floor, there is an unfinished basement and garage below the main floor. Any other suggestions?
    wmproop's Avatar
    wmproop Posts: 3,749, Reputation: 91
    Ultra Member
     
    #7

    Aug 11, 2010, 09:45 AM

    Are there open supply vents going to the basement and garage?
    If so close them off,tape over them if necessary, no use in cooling an area where not needed
    Jeni14's Avatar
    Jeni14 Posts: 9, Reputation: 1
    New Member
     
    #8

    Aug 11, 2010, 09:55 AM

    Yes, I have taped off the supply vents to the basement, and there aren't any in the garage.
    Joshdta's Avatar
    Joshdta Posts: 2,549, Reputation: 45
    Ultra Member
     
    #9

    Aug 11, 2010, 04:37 PM

    Take a water hose to your outdoor unit. This will help a good bit. The cleaner the better. Do not use a pressure washer.
    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #10

    Aug 11, 2010, 05:31 PM

    If your house is insolated well, and I mean really well, with the correct system installed you should be able to keep your home at a comfy 72 degrees on a 100 degree (outdoor temp) day. But at these temps, the unit will run most all day. You should be able to see between 14 and 20 degree differential between room temp and supply register temp if unit is working correctly(in most cases). Sounds like you need to have the system checked by a qualified ac tech. Good luck and please let us know what they have to say.
    spanky917's Avatar
    spanky917 Posts: 42, Reputation: 5
    Junior Member
     
    #11

    Aug 11, 2010, 07:41 PM

    Definitely need a qualified tech to evaluate... a properly designed & installed unit in a well insulated house with a well ventilated attic should have no problem on 100 degree day... just beware... if the tech also makes commission on sale of equipment... get more than one evaluation !

Not your question? Ask your question View similar questions

 

Add your answer here.


Check out some similar questions!

Air conditioner not cooling [ 1 Answers ]

A tech came out and replaced the expansion valve, and recharged the unit but it is not keeping our house cool during the day, and in the early morning when the temp. is at the set temp. the a/c will not cut off.

Air Conditioner Not Cooling [ 20 Answers ]

My air conditioner hasn't been cooling and I have had it on 70 degrees for the last 2 1/2 days hoping that it might cool down. Well it hasn't. It has been 80 degrees in here for the last two days. I called the maintenance man who works for my apartment complex and he looked at it and said there...

Air conditioner not cooling [ 2 Answers ]

I just purchased a new compressor last year. Seems like my air is not cooling. What could the problem be? Do we need to get the a/c serviced every year?

Air conditioner not cooling [ 3 Answers ]

My Carrier central air conditioner is 8 years old and it is not cooling. The vent blows air but the fan on the outside unit is not working. Any suggestions on how to fix it?

Air conditioner not cooling [ 0 Answers ]

My Carrier air conditioner is 8 years old and it is not cooling. The vent blows air but the fan on the outside unit is not working. Any suggestions on how to fix it?


View more questions Search