Home > Home & Garden > Heating & Air Conditioning   »   2 wire Single Stage Thermostat Issue

 
Thread Tools Search this Thread Display Modes
Question
 
 
#1  
Old Nov 14, 2005, 05:04 AM
RadMan
New Member
RadMan is offline
 
Join Date: Nov 2005
Posts: 1
RadMan See this member's comment history on his/her Profile page.
2 wire Single Stage Thermostat Issue

Thought this would be easy,

Here is the problem, the furnace stays on all the time even thought the programable themostat is set at a lower temperature than the room. The wiring must not be correct but there are only 2 wires. One for the transformer and one for the heat control. Please help!! Here is some information about my house.

I replaced a manual round thermostat with a Robertshaw 8600, Programmable Thermostat I have oil heat with an electric furnace with a Carlin EXPro Oil fired burner attachedand base board heating .

There were two wires connected to the manual thermostat, one to the R terminal and one to the Y terminal. I connected them as indicated in the wiring instructions, one to the RH terminal ( RH & RC terminals have a jumper between them ) and the other to the W1 terminal. There is a fan control switch that I selected Electric vs. Gas and a Heat Pump option switch that I have off.

What should I do?

Thanks in advance for your assistance.

RadMan

Reply With Quote
 
     

Answers
 
 
Old Nov 14, 2005, 12:16 PM   #2  
Über Member
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,646
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
Something is quite wrong. The Y terminal normally is used for A/C. The only way the I see old one would have kept the house warm would be if somebody connected in a relay to the W terminal at the furnace that gave power when the wire wasn't hot, and disconnected it when it was.

Go to the furncae and disconnect the wires to the thermostat. Turn the power to the furncae on, and see what happens. Then try it with a jumper between the 2 terminals the old thermostat was connected to. Post back, and I will try to figure it out.
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
6 wire AC/Heater to 5 Wire thermostat
(3 replies)
thermostat wiring issue
(2 replies)
honeywell thermostat heat/cool in Rheem 2 stage furnace?
(1 replies)
wiring a 2 wire thermostat to a 4 wire system
(1 replies)
2-wire thermostat replacement
(1 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 12:10 PM.