Home > Home & Garden > Heating & Air Conditioning   »   Furnace blower cycles with Thermostat off

 
Thread Tools Display Modes
Question
 
 
#1  
Old May 18, 2005, 07:08 AM
c9340
New Member
c9340 is offline
 
Join Date: May 2005
Posts: 1
c9340 See this member's comment history on his/her Profile page.
Furnace blower cycles with Thermostat off

Have Goodman Furnace built 1994. Worked fine until about 3 weeks ago.
It starts cycling, and the heat icon does not show on the thermostat. I turn the thermostat off, the furnace continues to blow. Last night to verify, took the thermostat off the wall (but still had the furnace plugged in and at 4:30 this morning, it turned on) had to unplug to stop. If I raise the thermostat above the current temp, the heater will turn on. Could it be the Control Circuit Board......other ideas? Had service tech out, of course it wouldn't repeat, but he said 80% circuit board 20% thermostat.....
When it begins it turns on for a couple of minutes, then turns off for a few more, then turns back on. Seems to do it mainly in the evening/early morning hours, we are not home during the day, but weekends it doesn't do it during the day. Thanx for anything you can suggest

Reply With Quote
 
     

Answers
 
 
Old May 18, 2005, 09:04 AM   #2  
Dogs Expert
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,615
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
The blower is controlled by a relay and timers or limit switches. On a heat cycle, the gas comes on, and then blower after a time or a temperature is reached. After the gas goes off, again either time or temperature shuts the blower off later. The off delay could be bad, or there could be a problem on the board. Most blower problems are due to a relay problem, but usually it is a problem of the relay either staying open or closed, not opening and closing on its own.

One other possible problem is a short between the contacts on the back of the thermostat. It does have a back that stays on the wall when you pull it? Pull the back off and look for any possible way for power to get from the red wire to the green wire. Also check at the furnace when the blower is running. See it you have 24 volts between the green and blue contacts.

Usually there is a 24 volt AC transformer in the furnace with the secondary winding connected to a red wire running to the thermostat and a blue wire, common, to the gas valve, A/C relay, and fan relay. From the thermostat there will be white wire to the gas valve, yellow to the A/C, and green to the fan. The thermostat is wired to switch the power from the red to the white, yellow, and green as needed with the blue completing the circuit. Most thermostats and furnaces have the contacts labeled R, B or C, W, Y, and G for the corresponding wire colors. It may be wired to have the A/C control wires return to the furnace and its controls and then a second wire goes to the A/C unit. Internal wiring may replace the green wire if the thermostat does not give you the option of fan only or continuous fan. Digital or programmable thermostats may need
  Reply With Quote
 
     
 
 
Old May 18, 2005, 04:47 PM   #3  
Dogs Expert
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,615
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
Sorry about that.

Digital or programmable thermostats may need the blue wire connected to them.

Likely a problem from me writing everything in NS 4.x and pasting it in. I am spelling typing impaired and haven't found anything to match its powerful and friendly spell check. The newer versions use a piece of trash copied from MS.
  Reply With Quote
 
     


Thread Tools
Display Modes

 
Similar Sponsors

Similar Threads
Question Asker Forum Answers Last Post
Thermostat Cycles Per Hour vin0607 Heating & Air Conditioning 3 Feb 11, 2006 04:58 PM
Furnace blower?? wmalcolm123 Heating & Air Conditioning 3 Dec 28, 2005 05:50 AM
Furnace Gives Heat but Cycles Frequently Jeorgiagirl Heating & Air Conditioning 4 Dec 17, 2005 05:07 AM
ac blower cycles on/off at start Jas 33 Heating & Air Conditioning 4 Nov 20, 2005 01:06 PM
Heatpump blower cycles on off Jas 33 Heating & Air Conditioning 1 Nov 20, 2005 12:42 PM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 10:22 PM.