Question
 
 
#1  
Old Jan 12, 2007, 10:07 AM
rlgibson9039
New Member
rlgibson9039 is offline
 
Join Date: Jan 2007
Posts: 1
rlgibson9039 See this member's comment history on his/her Profile page.
Fiquring Wind Load

Have set up a small Fire Training Facility in Florida and have been asked to give the side wind load in MPH.

Unit is 4 steel ocean containers stacked two high side by side and welded together and welded to concrete piers that are 36" deep and 19" in diameter. Whole unit set up is 17' tall x 16' wide x 40' long.

The sides are approximately 640 square feet of flat space and the ends are approx. 272 sq. ft. Total complex weighs about 42,000 lbs.

How do I fiqure what wind speed this complex will take?

Thanks,

Rick

Reply With Quote
 
     

Answers
 
 
Old Jan 13, 2007, 05:24 AM   #2  
Senior Electrical & Lighting Expert
tkrussell is offline
 
tkrussell's Avatar
 
Join Date: Jan 2005
Posts: 5,824
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
I do not believe there are any structural engineers on board here, so I did a quick search for "side wind load calculations".

Being an electrician, I need to be concerned with the wind load effect on exterior light fixtures and poles, which is relatively small, and simple to calculate, I was curious about your question.

Your situation is definitely much more complicated, as described by the following information:

http://www.aij.or.jp/jpn/symposium/2...pter6_com1.pdf

http://ocw.mit.edu/NR/rdonlyres/Civi...nd_eqloads.pdf

Wind Load Design Analysis: ASCE 7-98

For $110.00, here is a software package that claims to help with calculations "in 5 minutes or less": MECAWind05

And a "brief" explanation of an example calculation:
http://www.nssa.cc/NSSA/Assoc_standard_files/app_1.PDF


In addition to the wind load on the exposed surface of the structure, I would imagine that the connection of the structure to the "welded to concrete piers that are 36" deep and 19" in diameter" also be of concern.

Thou the static load of 42,000# should certainly be useful, I propose that if the total wind load due to the effective projected area of the structure combined with the wind speed could result in a wind load that could overcome the dead weight of the structure, the actual connection to the ground will be stressed, and should be considered and worked into any calculations.

You don't state how many piers there are, even if there are many, I do not believe that 36" deep piers are sufficient, of course, only if the wind load could actually lift 42,000#.

I get that wind load effect is a concern in Florida due to hurricane wind speed, and that effect on cladded structures that can disintegrate in that wind, but why are the inspectors concerned with a welded steel structure such as a shipping container.

What about all the loose containers stacked and lying around at the ports?

Ahh, now because they are used as a building structure?

I realize I did not actually answer your question, but hope I helped send you in the right direction.
  Reply With Quote
 
     
 
 
Old Jan 13, 2007, 05:43 AM   #3  
Senior Member
Nosnosna is offline
 
Join Date: Jan 2007
Location: East bumble, TN
Posts: 434
Nosnosna See this member's comment history on his/her Profile page.
I'm not a structural or civil engineer, so you shouldn't rely totally on me for this. Most of this is based on Physics I (Mechanics) and the problem-solving nature of any engineering field.

Unless I'm mistaken, what you need to consider are the strength of each weld (an absolute expressed in torque), the strength of the pier mooring (also an absolute expressed in torque), and the direct load of the wind against the exposed surface (absolute expressed by surface area and wind speed).

The effect of the load on any of the strengths will be based on the distance between the load and the weld/mooring point... a (relatively) simple moment of force calculation. Once you've found the relative strengths of each stress point, you will be able to find the max wind speed.

Odd geometries of the structure can produce strange results... you should consider specifics in any non-hypothetical case, as the load can vary greatly depending on the angle of the wind relative to the face of the structure.
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login



Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes
Ask your question or search...



Similar Threads
Wind Loads
(2 replies)
New A/C loud wind noise velocity on air return
(1 replies)
Wind load
(1 replies)
Averaging of wind speeds
(0 replies)
wind tunnel
(0 replies)

Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page
Search this Thread

Advanced Search

Bookmarks





Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 07:55 PM.