Home > Science > Energy   »   3 phase to 2 phase

 
Thread Tools Search this Thread Display Modes
Question
 
 
#1  
Old Sep 3, 2007, 11:35 AM
jcv
New Member
jcv is offline
 
Join Date: Sep 2007
Posts: 2
jcv See this member's comment history on his/her Profile page.
3 phase to 2 phase

How is it possible to go from a 3-phase circuit with 3 hots 120 degrees off from each other and a neutral, to a 2 phase circuit with just 2 hots and a neutral and have those 2 hots be now 180 degrees off from each other???

Reply With Quote
 
     

Answers
 
 
Old Sep 3, 2007, 12:09 PM   #2  
Senior Electrical & Lighting Expert
tkrussell is offline
 
tkrussell's Avatar
 
Join Date: Jan 2005
Posts: 5,749
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
For single phase all you need is any two legs of of the 3 phase system. For a neutral the system will need to have a grounded leg, which should be the center point of a WYE system.

What type of system do you have?

Comments on this post
jcv disagrees: I am still confused about the phase or in other words, the 120 degrees difference between the hot legs of a 3-phase as oppossed to the 180 degrees in the 2-phase
RubyPitbull agrees: Balancer. I am sooo tired of people jumping the gun here. Your response & follow up question was right on target. :)
  Reply With Quote
 
     
 
 
Old Sep 4, 2007, 03:32 PM   #3  
Senior Electrical & Lighting Expert
tkrussell is offline
 
tkrussell's Avatar
 
Join Date: Jan 2005
Posts: 5,749
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
How can you disagree with something your not sure about?

Did you notice I asked a question, therefore I am not done explaining?

Using two legs of a three phase system is not called "2 phase", it is single phase.

And each conductor is still 120 degrees apart.

Single phase is not 180 deg, one single phase circuit is 360 deg.

So, are you going to answer my question so we can have a dialog to get answers to your questions,or will you continue to complain?
  Reply With Quote
 
     
 
 
Old Sep 4, 2007, 05:14 PM   #4  
jcv
New Member
jcv is offline
 
Join Date: Sep 2007
Posts: 2
jcv See this member's comment history on his/her Profile page.
I apologize if I sounded argumentative before, it was not my intention.
I did not mean to rate answer before, I was not sure where to click to reply.
Anyway, you were asking what kind of system I have, my question was not related to my actual system, just curiosity in general. I understand that usually a 220v circuit with obviuosly 2 hot wires and a neutral is called single phase. This also puzzles me because what would you then call a 110v circuit?? single phase too??
Back to the 220v circuit, I meant that the 2 hot leads are 180 degrees off from each other, and if so since the 3 hot leads in a 3-phase circuit are 120 degrees off from each other I just can not understand how to use a 3-phase circuit to make a "single-phase"
220v circuit. Thanks, JCV
  Reply With Quote
 
     
 
 
Old Sep 5, 2007, 08:13 AM   #5  
Senior Electrical & Lighting Expert
tkrussell is offline
 
tkrussell's Avatar
 
Join Date: Jan 2005
Posts: 5,749
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
Ok, no problem.

Perhaps I can overload you wtih info. Review this site:The 3 Phase Power Resource Site - Three Phase Power Solutions.

3 phase can be a bit confusing, so pick thru the info at the website, see what you can understand, what do you already know, and we can go from there.
  Reply With Quote
 
     
 
 
Old Sep 5, 2007, 02:43 PM   #6  
Engineering & Electronics Expert
KeepItSimpleStupid is offline
 
KeepItSimpleStupid's Avatar
 
Join Date: Aug 2007
Posts: 9,154
KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.
Yep, 3-phase power is a bit difficult to understand.

Generally you will find 125, 208 and 277 and 480 in a plant or 440/220/120 in a plant that has 3 phase power depending if the transformation is Wye or Delta. 277 generally goes for lighting. Between any of L1, L2 AND L3 there will be 208 or 240 volts. 208 is 120 * sqrt(3). 277 = 480/sqrt(3)

Some buildings like ours have multiple power panels. We even had euopean voltages generated. Some parts of Japan use 100 V, where others use 120.

This is why the universal power supplies must be able to operate from about 95 V to 285 vac to make it universal.

In a single phase residential system you will find 120/240. Basically the center tap (120-0-120) of the transformer is grounded.
  Reply With Quote
 
     
 
 
Old Jul 15, 2009, 01:22 PM   #7  
New Member
James Lohr is offline
 
Join Date: Jul 2009
Posts: 1
James Lohr See this member's comment history on his/her Profile page.
You can convert 3-phase power to 2 phase power using a transformer in a a Scott-T configuration. See details of this on Wikipedia at:

Scott-T transformer - Wikipedia, the free encyclopedia

Not too many companies sell Scott-T transformers, but there are some you will find in a Google search.
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
2-phase vs 3-phase degrees of seperation
(3 replies)
Difference between 1-phase and 3-phase motors
(0 replies)
three phase vs. single phase
(2 replies)
Difference between single phase and 3-phase motors
(3 replies)
How am i going to size my 3 phase X'mer with 1 phase load using current as reference
(3 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 01:17 AM.