    Wiring pressure switch too well
    The line from the well has 3 wires where should the bare ground wire be attached? The line from the house has 3 wires where should the white ground wire be attached?
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #2

    Jan 27, 2013, 10:31 AM
    What colors do you have? 3wires is not common for a 240 volt pump and 120 would only need 2 plus a ground.The white is a neutral and not used in 240 volt pumps.
    donf's Avatar
    donf Posts: 5,679, Reputation: 582
    Printers & Electronics Expert
     
    #3

    Jan 27, 2013, 06:02 PM
    Please describe the wire from the home. Is it a black, white and bare ground?

    First, White is not a ground wire. It is by definition the grounded conductor, Neutral. It's purpose is to allow the return of the power to the system. The "white" may be a re-tasked conductor.

    In some situations the White conductor is re-tasked to be an un-grounded, Hot conductor
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #4

    Jan 27, 2013, 06:14 PM
    There are 2-wire and 3-wire well systems. Unless you have an unusually large capacity or or unusually deep well you will have a 2-wire. The wires from the well will probably be red and black and a ground which is either green or bare. The wires from the house will be black and white and a ground which will be bare. The ground wires from the well and the house will be connected to the 2 green ground screws in the switch box frame. The two wires from the house and the 2 wires from the well are connect to the switch electrical terminals. Most well pumps are 240 volts. Most of the time white designates a neutral. There is no neutral in a 240 volt circuit and in this case the white is a hot conductor. Put a piece of black electricians tape on it to redesignate it as a hot conductor and connect it to the switch terminal.
    stanfortyman's Avatar
    stanfortyman Posts: 5,598, Reputation: 279
    Electrical & Lighting Expert
     
    #5

    Jan 27, 2013, 08:03 PM
    The line from the well has 3 wires where should the bare ground wire be attached? The line from the house has 3 wires where should the white ground wire be attached?
    Assuming a deep well with a 240V pump:
    The green goes to one of the green screws in the pressure switch.

    In the house cable the black and the white are your two hots giving you 240V. There is no neutral in a 240V circuit.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Water pump pressure switch wiring [ 2 Answers ]

We lost water pressure in our house last night. We have a well pump 360 feet down. My 1st thought was the well pump has finally failed. I though a moment and remembered there is a pressure switch in the basement so decided to check that. The pressure read only 30. That seemed a little low. I...

I need a wiring diagram for a 16HP Vanguard V-Twin oil pressure switch. [ 2 Answers ]

Several years ago I purchased a Vanguard V-Twin, horizontal shaft engine and it's been in storage ever since. I did start and run it a couple of times a year. I am now going to put it into service. I had to install the wiring harness, but the book that came with it was one of those don't do this...

York residential furnace pressure switch problem code stuck switch [ 1 Answers ]

I have a york furnace P2MD12H06401A after 1 hour it shuts down and gives a 2 flash error for a stuck pressure switch. The switch is new can it be wired wrong? The old one had 2 white wires piggy back and 1 blue wire. The new switch has 3 separate terminals

Wiring a Water Pressure tank Switch [ 1 Answers ]

I am installing a new water pressure tank and am wiring up the pressure switch. It has 4 electric contact screws, the outside two are labeled L1 and L2. The middle two are M in a circle. The pump is wired 220. Which screw contact do I hook up to the service box and which to the pump, and do I...

Square D pressure switch wiring melting points. [ 7 Answers ]

Hi everyone, I am having problems with my well this week and right now have no water at all. I saw earlier in the week that the old pressure switch contacts were in very bad shape so I cleaned them but a day later it quit working. I bought a new switch this morning and put it in after about 10...


View more questions Search