Wire type for service Disconnect

I am installing an new service disconnect and meter base on the back of my garage/pole building. I have run wire underground from the new meter base to the house to get rid of the overhead and will be replacing the service to the house.

My question is what type of wire is needed out of the service disconnect (line side) to the weatherhead for the EC to hook up to the incoming line.

Next question is on the same lines. Going into the house will be a disconnect as it is too far from the main service disconnect. From there to the new breaker panel, which type of wire is to be used. This is a 200A service.

Thanks
Kevin

Reply With Quote
 
     

Answers
 
 
Old Oct 21, 2007, 03:45 AM   #2  
Senior Electrical & Lighting Expert
tkrussell is offline
 
tkrussell's Avatar
 
Join Date: Jan 2005
Posts: 6,392
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
You can use 4 wire aluminum URD cable, rated USE for direct burial. you can use a large conduit as a sleeve for extra protection, and under paved areas for easy replacement if needed.

Or you can use PVC Schedule 40 conduit with all the fittings for a continuous raceway system, and pull aluminum wires with XHHW insulation or THHN/THWN copper wire.

Inside you can use 4 wire aluminum SER cable.

For 200 amp residential, you can use 3- #4/0 Al or 3-#2/0 copper. The fourth wire, equipment grounding conductor, can be minimum #6 copper or #4 al.

Be sure to connect the neutral, equipment ground, and the grounding electrode conductor all together at the main disconnect. The neutral and equipment ground will be separated at the panel.
  Reply With Quote
 
     
 
 
Old Oct 21, 2007, 11:22 AM   #3  
New Member
KevinC is offline
 
Join Date: Oct 2007
Posts: 2
KevinC See this member's comment history on his/her Profile page.
Thank you Mr Russell
  Reply With Quote
 
     

Answer this question

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes
Ask your question or search...

 




Similar Threads
SPA disconnect switch grounding wire requirement
(1 replies)
200 amp service disconnect
(1 replies)
hard wire 3 wire to 4 wire 220 service
(1 replies)
hard wire 3 wire to 4 wire 220 service
(2 replies)
200 Amp Outside Service Disconnect
(5 replies)


Bookmarks and Sharing
bookmark twitter facebook

Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page
Search this Thread

Advanced Search




Copyright ©2003 - 2010 - Advizo, LLC
All times are GMT -8. The time now is 07:01 AM.