What's the standard height for light switches and outlet boxes?

Asked Mar 2, 2008, 10:03 PM — 11 Answers
It looks like most of the ones in the main part of the house are about 47" to the top of the switch box and around 18" to the top of the outlet boxes. Does it really matter by code or is it subjective? Also, what size wire is recommended for lighting and outlets in a finished basement? 12/2 w/ ground or 14/2 w/ground?

11 Answers
biggsie's Avatar
biggsie Posts: 1,277, Reputation: 677
Ultra Member
 
#2

Mar 2, 2008, 11:00 PM
Use a standard 16 oz. Straight claw hammer for receptacle height.

This puts the bottom of the outlet box about 13" above the floor.

For light switches, go 42" to the bottom of the switchbox.

For counter top receptacles/switches go 46" to the bottom of the box.
Helpful
stanfortyman's Avatar
stanfortyman Posts: 4,922, Reputation: 1351
Electrical & Lighting Expert
 
#3

Mar 3, 2008, 03:49 AM


Quote:
Originally Posted by Dave Ermeling
It looks like most of the ones in the main part of the house are about 47" to the top of the switch box and around 18" to the top of the outlet boxes. Does it really matter by code or is it subjective?
Completely subjective.
The only times it matters is if you have to follow ADA requirements, which don't apply in your home, and for "required" receptacles you can't be higher than 5.5' and now lower then literally in the floor within18" of the wall.
Once the minimum receptacles have been met you can put them in the middle of the floor or the middle of the ceiling if you want.

I use 48" TTT (to the top) for switches; kitchen counter, garage, unfinished basement receptacles.
44" TTT for bath vanity receptacles.
16" TTT for regular receptacles. (Don't get me started on "hammer height" )






Quote:
Originally Posted by Dave Ermeling
Also, what size wire is recommended for lighting and outlets in a finished basement? 12/2 w/ ground or 14/2 w/ground?
Whatever you want. Some rooms, like kitchen, laundry and bath receptacles DO require 20A circuits, but for a general habitable room use what you want. I' use 14/2.
Helpful
Stratmando's Avatar
Stratmando Posts: 10,531, Reputation: 2530
Uber Member
 
#4

Mar 3, 2008, 06:04 AM
I use 18" to the center(20 to the top)for recepticles.
48' to the center for switches, 42' for kitchen and vanitys.
80 " to the center for Bath and porch lights.
Back splashes, counters, ceilings may need to alter these heights.
We can't use #14, if I could,I would still use #12 on a 20?
Helpful
Dave Ermeling's Avatar
Dave Ermeling Posts: 173, Reputation: 10
Junior Member
 
#5

Mar 3, 2008, 11:26 AM
Wow, it seems to really vary. Thanks for all the answers guys. One other thing-At what height does everyone drill the holes for running the outlet wiring? And what size hole?
Helpful
mbackususmc's Avatar
mbackususmc Posts: 7, Reputation: 1
New Member
 
#6

Mar 3, 2008, 01:33 PM
Quote:
Originally Posted by Dave Ermeling
It looks like most of the ones in the main part of the house are about 47" to the top of the switch box and around 18" to the top of the outlet boxes. Does it really matter by code or is it subjective? Also, what size wire is recommended for lighting and outlets in a finished basement? 12/2 w/ ground or 14/2 w/ground?
In NFPA 101 it says that the handle of a switch should be no higher than 48" so I have always put switches at 46" bottom of the box and receptacles seem to work well at 14" to bottom. Vanities kitchens and unfinished areas are 43" which allows enough room in a bath or kitchen for your backsplash and to answer about your hole drilling, I have always found that 99% of the time it is less time consuming to drill the top plates with a 1 1/8" auger in a right angle drill, however if you drill parallel to the floor you will find it easier if you hold the right angle at hip height, this will also give you a consistent height which will make pulling the wires easier.
Helpful
stanfortyman's Avatar
stanfortyman Posts: 4,922, Reputation: 1351
Electrical & Lighting Expert
 
#7

Mar 3, 2008, 01:42 PM


Where are you that you must follow NFPA 101 for residential work?

Also, I hope you are not drilling a 1 1/8" hole in 2x4 lumber.
Helpful
Stratmando's Avatar
Stratmando Posts: 10,531, Reputation: 2530
Uber Member
 
#8

Mar 3, 2008, 04:12 PM
I use 7/8" for 1/2 inch PVC and ENT(Smurf), 1 1/8" for 3/4 PVC and Smurf. You will need nail plates if hole is 1 1/4" from edge of stud. Drill 7/8"in center and you won't need a nail plate, Don't Notch.
Helpful
mbackususmc's Avatar
mbackususmc Posts: 7, Reputation: 1
New Member
 
#9

Mar 3, 2008, 04:13 PM
I mainly work in commercial however I use the ada requirement found in 101 as a guideline (esp since I do a lot of FA installation). 1 1/8 is the maximum allowable size hole (when centered) allowed by code in a 3 1/2" 2x4 wall (if not centered you can still do it by using a stud guard
Helpful
mbackususmc's Avatar
mbackususmc Posts: 7, Reputation: 1
New Member
 
#10

Mar 3, 2008, 04:14 PM
This is by my local codes (IA) perhaps yours vary
Helpful

Not your question? Ask your question View similar questions

 
Thread Tools Search this Thread
Search this Thread:

Advanced Search



Check out some similar questions!

Standard for kitchen supply and waste height off floor? [ 10 Answers ]

Is there a standard height off the floor for the cold/hot water supplies and the waste pipe or drain (the part the P trap goes into). I ripped out what was there before as the sink was a long distance from the waste pipe (terminoloy?) and the pitch was towards the sink and not the drain. I...

Is dust in electrical outlet boxes a fire hazard? [ 12 Answers ]

I've been changing out all my electrical outlets and switches because they were beige and I like white...anyway I find that some of the electrical outlet boxes are full of dust. I pulled out the shop vac and took care of it and I noticed it was outlets that are powering something constantly (ie:...

Standard height [ 17 Answers ]

Is there a standard height for a wall fixture over a mirror above a vanity?

Outlet boxes and wiring installed on basement wall [ 1 Answers ]

What is the proper method of wiring outlets on the basement wall. The wall has 2x3 firring strips 16" OC. Does the wire have to be in conduit?

3 problems: GFI outlet, ceiling fans, light switches [ 1 Answers ]

This morning, my bathroom gfi outlets in all bathrooms won't work. The one with the black trip button and red reset button won't allow me to push the button in to trip/break. Also, I have tripped/reset my kitchen outlets and tripped/reset ALL the breakers in my outside box. Still won't work, trip...


View more Electrical & Lighting questions Search