Question
 
 
#1  
Old Aug 23, 2008, 12:54 PM
searchitnow
New Member
searchitnow is offline
 
Join Date: Aug 2008
Posts: 1
searchitnow See this member's comment history on his/her Profile page.
Underground wiring - well pump

Hi

I am trying to run this AWG 6-2CU UF-B underground feeder cable from the basement to an outdoor well pump controller. This is a three wire (two isolated + ground) cable that is to be connected at 240Vac from the main panel and routed out for about 200ft. The controller is supposed to limit the current to 20A.
I had the 18" deep outdoor trench dug, and I would like to protect the cable on most of its outdoor length.
I read however some post (not on thi site) stating that one cannot run underground wire through conduit on the entire length of the cable because of possible cable outgasing. I still want my cable protected though, for future landscaping projects.
1. If I want to use some plastic pipe to protect the cable how often should I cut the pipe then? 2. What less expensive options do I have trying to protect the underground cable?

I am also contemplating running in the same trench (at 8” depth though) an irrigation pipe.
3. Would this create any issue from an NECode stand point?

Thank you for help

Reply With Quote
 
     

Answers
 
 
Old Aug 23, 2008, 01:19 PM   #2  
Electrical & Lighting Expert
stanfortyman is offline
 
Join Date: Feb 2008
Posts: 2,529
stanfortyman See this member's comment history on his/her Profile page.stanfortyman See this member's comment history on his/her Profile page.
You certainly can put that cable in conduit, problem is it will need to be pretty big, like 1-1/4 or 1-1/2 inch. If it were me I'd use 1-1/2" PVC Sch80.
6/2UF cable is quite large.

No problem from an electrical code standpoint to have the water above the electric.
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
underground wiring
(5 replies)
Outdoor underground ejector pump & pit venting
(8 replies)
underground wiring
(1 replies)
underground wiring
(1 replies)
underground wiring
(1 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 03:36 PM.