    jimboace's Avatar
    jimboace Posts: 2, Reputation: 1
    New Member
     
    #1

    Nov 5, 2007, 10:53 AM
    Should I bond neutral and ground in my box?
    I have just had 3 cables of #4 aluminum wire run from my main panel to a new sub panel in my shed. I have them wired as 2 hot, 1 neutral. Maybe I should have run a fourth wire for ground, but too late for that since its buried 2 feet down.

    With three wires coming from my main to my shed, do I need to bond the neutral and equipment ground in the sub panel box? I installed an equipment ground connector in the box and a grounding rod and I know that generally the neutral and equipment ground are isolated in a sub panel, but what about when only three wires (2 hot, 1 neu) are coming from the main?

    I can live with 120v in the shed if I have to, so I can redo the main to send 1 hot, 1 neutral, 1 ground to the subpanel with my three wires. In that case, I assume I definitely do NOT want the neutral and ground bonded at the subpanel, right?

    I am not turning on any power until I'm sure I have it right.
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #2

    Nov 5, 2007, 04:34 PM
    This will be disallowed in the new code, but now you need to bond the neutral to the ground, and use the rod as you mentioned. This will give you 120/240 volts.

    Check with local code to see if another rod is needed.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Neutral and Ground share the same connection? [ 1 Answers ]

I have a question regarding wiring for my Hot Springs Spa. The spa comes with a subpanel for two GFCI breakers, one 20-amp and one 30-amp. I have 220 wired to an existing subpanel located right next to my spa location. The only difference between my sub panel and the wiring diagram on the spa...

Open ground when neutral not touching ground [ 3 Answers ]

Hi, I was moving around a room and noticed my wife wanted her desk elsewhere. I decided to, since she would have her computer on it, check the outlet she would be moving to. It seemed old so I changed it. I noticed before I changed it that with my GFCI tester, all sockets on this circuit were...

Neutral to Ground Bond [ 4 Answers ]

This should be a straightforward question and answer but so far everyone I've asked has given me the "it's a local code issue" or in my opinion the wrong answer. I have a 12KW standby generator permanently installed at my home. The ATS is a two-pole transfer with a solid neutral. The generator...

Ground and neutral bar [ 2 Answers ]

I'm installing a 4 wire, 50 AMP GFCI for my hot tub. My question is at my main breaker for the house where I'm taking power from, which bar is neutral and which bar is ground, or does it matter? Thanks Fred

Using Neutral as a Ground ? [ 3 Answers ]

In my new apartment there are some wall outlets that are two prong outlets. Also my fear is that the three prong outlets are not “physically” connected to ground. I heard somewhere that in this kind of system the neutral wire can also be used as a ground. Is this correct? Would a separate...


View more questions Search