Service Size

Is a 100 amp service on a 640 square foot house with electric baseboard heating adaquate?

Reply With Quote
 
     

Answers
 
 
Old Nov 2, 2009, 02:26 PM   #2  
Über Member
Stratmando is offline
 
Stratmando's Avatar
 
Join Date: May 2007
Location: Florida Keys
Posts: 6,265
Stratmando See this member's comment history on his/her Profile page.Stratmando See this member's comment history on his/her Profile page.Stratmando See this member's comment history on his/her Profile page.
Sounds Like enough. Can you list all Appliances, Gas Dryer? Kiln, Welder, Dock, Jacuzzi, InstaHeat(Demand Water Heater)
  Reply With Quote
 
     
 
 
Old Nov 2, 2009, 03:57 PM   #3  
New Member
rustydog is offline
 
Join Date: Nov 2009
Posts: 3
rustydog See this member's comment history on his/her Profile page.
There is an electric dryer stove and hot water tank
  Reply With Quote
 
     
 
 
Old Nov 2, 2009, 03:59 PM   #4  
New Member
rustydog is offline
 
Join Date: Nov 2009
Posts: 3
rustydog See this member's comment history on his/her Profile page.
Quote:
Originally Posted by Stratmando View Post
Sounds Like enough. Can you list all Appliances, Gas Dryer? Kiln, Welder, Dock, Jacuzzi, InstaHeat(Demand Water Heater)
There is an electric stove dryer and hot water tank
  Reply With Quote
 
     
 
 
Old Nov 2, 2009, 05:04 PM   #5  
Electrical & Lighting Expert
stanfortyman is offline
 
Join Date: Feb 2008
Posts: 2,537
stanfortyman See this member's comment history on his/her Profile page.stanfortyman See this member's comment history on his/her Profile page.
How much heat? New construction would dictate around 4,000 -5,000 watts.
  Reply With Quote
 
     
 
 
Old Nov 2, 2009, 07:21 PM   #6  
Junior Member
eriknugent is offline
 
Join Date: Sep 2008
Posts: 80
eriknugent See this member's comment history on his/her Profile page.
your calculating out to about 65.5 amps without the heat if stan i right that pushes you up to 86.3 amp if i where you i would go with a 150A give you some room to expand and your not talking that much of an increase in price.
  Reply With Quote
 
     
 
 
Old Nov 2, 2009, 07:27 PM   #7  
Full Member
ohb0b is offline
 
Join Date: Apr 2009
Posts: 200
ohb0b See this member's comment history on his/her Profile page.
Doing as much of a standard calculation as info gives:

General Lighting Load: 640 sq. ft x 3VA/sq.ft=1920 VA
2 kitchen Circuits= 3000 VA
laundry Circuit=1500 VA

Total: 6420 VA

1st 3KVA @ 100%----------3000VA
Remainder at 35%---------1197 VA==========3197 VA
Dryer----------------------------------------------------5000 VA
Range----------------------------------------------------8000 VA?
Water Heater--------------------------------------------5000 VA?
Baseboard Heat-----------------------------------------4000 VA?

Total VA-------------------------------------------------25197 VA

25197VA/240 Volts=105 amps

Standard Calculation put you over. If you are allowed to compute the Optional Method, (Check with your local inspector) Using the same information:

General Lighting load: 1920 VA
Kitchen and Laundry: 4500 VA
Dryer------------------5000VA
Range-----------------8000VA?
Water Heater------- 5000 VA?
Baseboard Heat------4000 VA?

Total VA---------------28420 VA

First 10,000 VA @ 100%----------10,000 VA
Remainder at 40%----------------7296 VA

Total VA........................................17296 VA
17296 VA/240 Volts===========72 amps


Still cutting it close! Not much room for expansion there. Have you considered gas heat, hot water and range?
  Reply With Quote
 
     
 
 
Old Nov 3, 2009, 02:04 PM   #8  
Senior Electrical & Lighting Expert
tkrussell is offline
 
tkrussell's Avatar
 
Join Date: Jan 2005
Posts: 5,824
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
Need to correct a few errors in this calculation, and added some clarity, my corrections in red:

Quote:
Originally Posted by ohb0b View Post
Doing as much of a standard calculation as info gives:

General Lighting Load: 640 sq. ft x 3VA/sq.ft= 1920 VA
2 kitchen Circuits= 3000 VA
1 Laundry Circuit= 1500 VA
Total: 6420 VA

1st 3KVA @ 100%----3000 VA
Remainder at 35%----1197 VA
Subtotal................. 4197 VA
Dryer----------------5000 VA
Range---------------8000 VA Allowed Load for one range in dwelling
Water Heater--------4500 VA Typical Load for typical WH
Baseboard Heat------4000 VA? As good a guess as anyone, thou should be higher

Total VA------------25697 VA

25697VA/240 Volts = 107 amps

Standard Calculation put you over.

If you are allowed to compute the Optional Method, (Check with your local inspector)

Per code, the designer is allowed to use the optional methods, rarely does an inspector have any say in this, as the designer is the responsible party in sizing the service.


Using the same information:

General Lighting load: 1920 VA
Kitchen and Laundry: 4500 VA
Dryer------------------5000 VA
Range-----------------8000 VA
Water Heater----------4500 VA
Baseboard Heat------ 4000 VA?

Total VA--------------27920 VA

First 10,000 VA @ 100%--10,000 VA
Remainder,17920 at 40%---7168 VA

Total VA.........................17168 VA
17168 VA/240 Volts======72 amps


Still cutting it close! Not much room for expansion there. Have you considered gas heat, hot water and range?
Sorry OH, but there was a math/typo error in the beginning of the calcs, but with me changing the size WH load, still brought the results close.

A 100 amp service, based on the little information given, and assumptions on the heat KW, is sized adequately.

This is why I dislike doing these calcs, as the info needed is critical.
  Reply With Quote
 
     
 
 
Old Nov 3, 2009, 02:19 PM   #9  
Full Member
ohb0b is offline
 
Join Date: Apr 2009
Posts: 200
ohb0b See this member's comment history on his/her Profile page.
Sorry for the typo and math error. I thought I double checked it.. but remember I added 3000 and 1197 in my head, instead of using a calculator!

yeah, I don't know anyone who has ever used the standard calculation. I just assumed there might have been a local requirement in some jurisdictions to use it.

Personally, I put everything I can on natural gas.
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login



Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes
Ask your question or search...



Similar Threads
Service Size
(1 replies)
what size service?
(13 replies)
service entrance cable size for 100 amp and 200 amp service.
(1 replies)
Size of service
(1 replies)
WHAT WOULD BE The best size AWG to use for an 80 and 100 amp service
(2 replies)

Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page
Search this Thread

Advanced Search

Bookmarks





Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 03:01 AM.