Home > Home & Garden > Electrical & Lighting   »   electric range wiring

 
Question Tools Search this Question Display Modes
Question
 
 
#1  
Old Feb 16, 2008, 06:22 AM
jbdmjhcc
New Member
jbdmjhcc is offline
 
Join Date: Feb 2008
Posts: 2
jbdmjhcc See this member's comment history on his/her Profile page.
electric range wiring

4 years ago my home passed electrical inspection with the range wired on a 10/3 wire in a 30 amp breaker. Today I am finishing out the basement and the inspector tells me I need a 40 amp breaker with a 6/3 wire. Has the NEC changed regarding this?

Reply With Quote
 
     

Answers
 
 
Old Feb 16, 2008, 06:33 AM   #2  
stanfortyman
Electrical & Lighting Expert
stanfortyman is offline
 
Join Date: Feb 2008
Posts: 923
stanfortyman See this member's comment history on his/her Profile page.
No, the code has not changed.
An inspector does not care what size range you put in. For all he knew you were going to use a dual-fuel range that would typically take a 30A circuit. It is NOT his responsibility to catch this type of violation. Whoever installed the range is at fault, NOT the inspector.

Is this a free standing all electric range?
If so then you do need either a 40 or 50 amp circuit. The size of the range does matter, but only if it is really big. By this I mean 12.5Kw or larger.

For a 40A circuit you can use 8/3NM, for a 50A or 60A circuit you can use 6/3NM.
  Reply With Quote
 
     
 
 
Old Feb 16, 2008, 06:35 AM   #3  
Stratmando
Ultra Member
Stratmando is offline
 
Stratmando's Avatar
 
Join Date: May 2007
Location: Florida Keys
Posts: 3,827
Stratmando See this member's comment history on his/her Profile page.Stratmando See this member's comment history on his/her Profile page.
It May be the Range, May even need 50 Amp breaker on #6. New Construction and remodel of Kitchen need 4 Wire Range recepticle and Cord. Existing can be 3 wire.
Need Specs on Range. Inspector may have noticed Range Name Plate.
  Reply With Quote
 
     
 
 
Old Feb 16, 2008, 06:49 AM   #4  
jbdmjhcc
New Member
jbdmjhcc is offline
 
Join Date: Feb 2008
Posts: 2
jbdmjhcc See this member's comment history on his/her Profile page.
I'm not sure if this is the information you are asking for but. Inputs @ 240V are 6,685 Watts
  Reply With Quote
 
     
 
 
Old Feb 16, 2008, 07:13 AM   #5  
stanfortyman
Electrical & Lighting Expert
stanfortyman is offline
 
Join Date: Feb 2008
Posts: 923
stanfortyman See this member's comment history on his/her Profile page.
A circuit of 8/3NM and a two-pole 40A breaker are fine for this.
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
Electric range timer wtdennis Appliances 1 Jan 20, 2008 05:23 AM
Changing from a gas range to an electric smooth top range nical99 Appliances 1 Jul 8, 2007 08:14 AM
Electric Range Wiring drcajjr Electrical & Lighting 4 May 25, 2007 06:57 AM
electric range grode Appliances 2 May 1, 2007 01:45 AM
GE Electric Range darroyos Appliances 6 Oct 29, 2006 03:00 PM