Ask Experts Questions for FREE Help!
Answer   ||    Advanced Search

Ask your question or search...
International Sites: Nederlandse experts vragen
User Name 
Password 
Join   Forgot password? 

Home > Home & Garden > Electrical & Lighting   »   Really***read this first***"Best Of" and Other important Information

Question
 
 
#1  
Old Sep 30, 2009, 03:14 PM
tkrussell's Avatar
tkrussell
Senior Electrical & Lighting Expert
tkrussell is offline
 
Join Date: Jan 2005
Posts: 5,824
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
Really***read this first***"Best Of" and Other important Information

Well, finally going to get this started, a Sticky with what we believe are some of the more interesting threads that can be found posted in the Electrical and Lighting Forum.

Plus look for reference materials, tables, charts, Code sources, etc.

This will be a work in progress, regarding format, content, information, etc.

Suggestions will always be welcomed.

As this thread grows and evolves, it, I believe, will be the first stop that should be taken to help with understanding the vast details of the electrical industry. We find that often we need to explain some details of the systems before we can get to the real answer of the topic.


LOCATION, LOCATION, LOCATION.

We need to know in which country, sometimes state, that your located, so that we can give accurate answers.

Stay tuned. And check back often, (hopefully).

Reply With Quote
 
     

Answers
 
 
Old Oct 1, 2009, 02:47 AM   #2  
Senior Electrical & Lighting Expert
tkrussell is offline
 
tkrussell's Avatar
 
Join Date: Jan 2005
Posts: 5,824
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
Correction for Residential Feeder Sizing Advice

Ok, I guess I will get this started with this information, and basically a correction of previous advice given, by me and others:

This is as good a place as any to mention this, Table 310.15 (B) 6 of the NEC is not allowed for subpanel feeders. I had misused this table myself in the past. So, #4 copper, for example, cannot be used to feed a 100 amp subpanel, only to feed the main service.

All experts, and any others that offer advice here, please take notice, and cease and desist from offering Table 310.15 (B) 6 wire sizes for residential feeders.

Table 310.15 (B) (6) is to only be used for conductors SUPPLYING the main service panel or disconnect.

After then Main Panel, , Table 310.16 must be used to size feeder conductors.
  Reply With Quote
 
     
 
 
Old Oct 1, 2009, 02:54 AM   #3  
Senior Electrical & Lighting Expert
tkrussell is offline
 
tkrussell's Avatar
 
Join Date: Jan 2005
Posts: 5,824
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
Shocks from Swimming Pool

Here is a thread that deals with getting shocks from a pool:

http://www.askmehelpdesk.com/electri...ol-118962.html
  Reply With Quote
 
     
 
 
Old Oct 2, 2009, 02:47 AM   #4  
Senior Electrical & Lighting Expert
tkrussell is offline
 
tkrussell's Avatar
 
Join Date: Jan 2005
Posts: 5,824
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
This thread is one of my favorites, had good information about the false ratings of small air compressors:

http://www.askmehelpdesk.com/electri...gs-291599.html
  Reply With Quote
 
     
 
 
Old Oct 2, 2009, 02:56 AM   #5  
Senior Electrical & Lighting Expert
tkrussell is offline
 
tkrussell's Avatar
 
Join Date: Jan 2005
Posts: 5,824
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
This one addresses getting mild shocks from pools:

http://www.askmehelpdesk.com/electri...ol-118962.html
  Reply With Quote
 
     
 
 
Old Oct 16, 2009, 01:06 PM   #6  
Senior Electrical & Lighting Expert
tkrussell is offline
 
tkrussell's Avatar
 
Join Date: Jan 2005
Posts: 5,824
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
Poor Voltage Causing Problems

A post about poor voltage issues:

http://www.askmehelpdesk.com/electri...ng-382186.html
  Reply With Quote
 
     
 
 
Old Oct 18, 2009, 04:22 AM   #7  
Senior Electrical & Lighting Expert
tkrussell is offline
 
tkrussell's Avatar
 
Join Date: Jan 2005
Posts: 5,824
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
Correction on Feeder Sizes

Past advice for feeders have been to use Table 310.15 (B) 6 for any residential feeder.

This table is ONLY for feeders supplying current for the entire service.

Beyond the service entrance feeder, Table 310.16 must be used.

A good explanation, and confirmation of this was found here:

http://www.ci.bend.or.us/depts/commu...um_200_amp.pdf
  Reply With Quote
 
     
 
 
Old Oct 18, 2009, 04:24 AM   #8  
Senior Electrical & Lighting Expert
tkrussell is offline
 
tkrussell's Avatar
 
Join Date: Jan 2005
Posts: 5,824
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
Any Interest in this Thread???

I was under the impression that others had information that could be added to this thread.

Or ideas of what would be good to post.

I see no interest so far.
  Reply With Quote
 
     
 
 
Old Oct 18, 2009, 06:33 AM   #9  
Home Improvement & Construction Expert
hkstroud is offline
 
Join Date: Jan 2008
Location: Alex, VA
Posts: 4,134
hkstroud See this member's comment history on his/her Profile page.hkstroud See this member's comment history on his/her Profile page.hkstroud See this member's comment history on his/her Profile page.hkstroud See this member's comment history on his/her Profile page.
Yes, there is interest, just don't have skill or knowledge to add to it.
  Reply With Quote
 
     
 
 
Old Oct 19, 2009, 02:34 AM   #10  
Senior Electrical & Lighting Expert
tkrussell is offline
 
tkrussell's Avatar
 
Join Date: Jan 2005
Posts: 5,824
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
HK you just did by replying to this thread. Just add a link to a thread you like, or add some info you think will help others in your reply.
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login



Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes
Ask your question or search...



Similar Threads
READ THIS. important warning
(8 replies)
Important correction, a must read on inmate funds for college
(3 replies)
Important Stock Information
(4 replies)
Important Info...moms Need To Read....
(11 replies)

Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page
Search this Thread

Advanced Search

Bookmarks





Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 08:47 PM.