Home > Home & Garden > Electrical & Lighting   »   Maximum VA load on a 20 amp CB

 
Thread Tools Search this Thread Display Modes
Question
 
 
#1  
Old Mar 27, 2009, 03:14 PM
Tonylac
New Member
Tonylac is offline
 
Join Date: Mar 2009
Posts: 2
Tonylac See this member's comment history on his/her Profile page.
Maximum VA load on a 20 amp CB

What is the maximum load on a480/277, 3 phase, 4 wire panel with a 20 amp, 2 pole circuit breaker, is there a chart that I can use, using different voltage systems? What is
the rule of thumb if you need to go to the next higher CB rating?

Reply With Quote
 
     

Answers
 
 
Old Mar 27, 2009, 03:40 PM   #2  
Electrical & Lighting Expert
stanfortyman is offline
 
Join Date: Feb 2008
Posts: 2,531
stanfortyman See this member's comment history on his/her Profile page.stanfortyman See this member's comment history on his/her Profile page.
A 20A breaker can handle a load of 20 amps. The voltage is incidental.
You go to the next higher breaker when the load is too much for the circuit. Many commercial circuits are considered a continuous load so that you can only load a circuit to 80%.

What is the basis of your question? What is the application?
  Reply With Quote
 
     
 
 
Old Mar 27, 2009, 07:49 PM   #3  
Engineering & Electronics Expert
KeepItSimpleStupid is online now
 
KeepItSimpleStupid's Avatar
 
Join Date: Aug 2007
Posts: 9,339
KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.
3 phase, 2 pole?
  Reply With Quote
 
     
 
 
Old Mar 28, 2009, 02:55 AM   #4  
Senior Electrical & Lighting Expert
tkrussell is offline
 
tkrussell's Avatar
 
Join Date: Jan 2005
Posts: 5,816
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
Are you trying to calculate load on the entire panel, or just the 20 amp circuit?

Single Phase VA (Volt-Amperes) = Volts times Amps for the two pole circuit.
Three Phase VA (Volt-Amperes) = Volts times Amps times 1.73 for the panel.

Quote:
Originally Posted by Tonylac View Post
What is the maximum load on a480/277, 3 phase, 4 wire panel with a 20 amp, 2 pole circuit breaker, is there a chart that I can use, using different voltage systems? What is
the rule of thumb if you need to go to the next higher CB rating?
There are no charts, we use Ohm's Law calculations.

There are no "rules of thumb", we use the National Electric Code.

Answer Stan's questions to get better answers.

Sure,:
Quote:
Originally Posted by KeepItSimpleStupid
3 phase, 2 pole?
Why not? A 480 volt single phase load can be supplied by a 3 phase panel.
  Reply With Quote
 
     
 
 
Old Mar 30, 2009, 10:38 AM   #5  
New Member
Tonylac is offline
 
Join Date: Mar 2009
Posts: 2
Tonylac See this member's comment history on his/her Profile page.
Quote:
Originally Posted by stanfortyman View Post
A 20A breaker can handle a load of 20 amps. The voltage is incidental.
You go to the next higher breaker when the load is too much for the circuit. Many commercial circuits are considered a continuous load so that you can only load a circuit to 80%.

What is the basis of your question? What is the application?

I am trying to learn how to fill out a 480/277v, 3p, 4w panel. I have a load of 5425/phase.
Is 20a-2p cb good?

Also, how do you convert kw to kva using 80% P.F.?
Thanks a lot guys.
  Reply With Quote
 
     
 
 
Old Mar 30, 2009, 11:32 AM   #6  
Engineering & Electronics Expert
KeepItSimpleStupid is online now
 
KeepItSimpleStupid's Avatar
 
Join Date: Aug 2007
Posts: 9,339
KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.
Do you have a 3 phase load or a single phase load?

5425/phase generally indicates a 3 phase load.

And your talking about 2 pole breakers or say a 480 single phase load.

277 I'd have to do some research.Not sure if they are 2 pole or single pole breakers.

80% pf means multiplying by 1/(0.80) or 1.25
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
How to determine Dead load & Wind load calculations
(0 replies)
Kenmore front load washer won't agitate/spin if load too heavy
(1 replies)
maximum load allowed on a branch circuit used for fixed resistance heating?
(1 replies)
Maximum load on 15A circuit
(5 replies)
Maximum load on 20 amp circuit breaker
(2 replies)