#1  
Old Mar 22, 2007, 01:24 PM
rwb461
New Member
rwb461 is offline
 
Join Date: Mar 2007
Posts: 3
rwb461 See this member's comment history on his/her Profile page.
Leakage currents

To make a lengthly story short, I have found leakage current of about 120ma. in a one year old dishwasher. It seems to me that if this appliance lost its' ground, that it would be a lethal condition. Is that amount of leakage normal for a "new' appliance? GFI outlets are must trip at 7ma. What is going on?

Reply With Quote
 
     

Answers
 
 
Old Mar 22, 2007, 01:38 PM   #2  
ballengerb1
Home Repair & Remodeling Expert
ballengerb1 is offline
 
Join Date: Dec 2006
Location: Wheaton, Illinois, USA
Posts: 8,427
ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.
How did you detect the leakage/short? If your washer is on a GFI it should have tripped as you suspect. Even if the green ground wire came lose it would not cause this situation but check to insure it is still securely in place. Do this with the power off.

Comments on this post
rwb461 agrees: Please see my next offering.
  Reply With Quote
 
     
 
 
Old Mar 23, 2007, 03:29 AM   #3  
labman
Dogs Expert
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,600
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
I would cut power to it until tkrussel checks in.

Comments on this post
rwb461 agrees: He speaks the truth!
  Reply With Quote
 
     
 
 
Old Mar 23, 2007, 12:27 PM   #4  
rwb461
New Member
rwb461 is offline
 
Join Date: Mar 2007
Posts: 3
rwb461 See this member's comment history on his/her Profile page.
Quote:
Originally Posted by ballengerb1
How did you detect the leakage/short? If your washer is on a GFI it should have tripped as you suspect. Even if the green ground wire came lose it would not cause this situation but check to insure it is still securely in place. Do this with the power off.
Thank you for your attention. The machine is not on a GFI. The current was measured from neutral to ground. What bothers me is the high amount of leakage. If a GFI must trip at 7ma, why should my dishwasher be draining 120ma under similar circumstance that would cause a GFI to trip, IF THE GROUND IS LOST?
  Reply With Quote
 
     
 
 
Old Mar 23, 2007, 02:59 PM   #5  
ballengerb1
Home Repair & Remodeling Expert
ballengerb1 is offline
 
Join Date: Dec 2006
Location: Wheaton, Illinois, USA
Posts: 8,427
ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.
First I would consider putting this machine on GFI but tkrussell's forthcoming advice will be very important. I put all electric circuits on GFI if they are anywhere near water or plumbing. This may be over protection but no live person has ever complained. I would also check the neutral to ground after completely disconnecting from the washer. This line may not be dedicated and you are picking up useage down the line. Tk will be here shortly I'm sure.
  Reply With Quote
 
     
 
 
Old Mar 23, 2007, 05:11 PM   #6  
rwb461
New Member
rwb461 is offline
 
Join Date: Mar 2007
Posts: 3
rwb461 See this member's comment history on his/her Profile page.
Quote:
Originally Posted by ballengerb1
First I would consider putting this machine on GFI but tkrussell's forthcoming advice will be very important. I put all electric circuits on GFI if they are anywhere near water or plumbing. This may be over protection but no live person has ever complained. I would also check the neutral to ground after completely disconnecting from the washer. This line may not be dedicated and you are picking up useage down the line. Tk will be here shortly I'm sure.

Where do I find a GFI that is'nt a must trip at 7ma?
  Reply With Quote
 
     
 
 
Old Mar 23, 2007, 06:49 PM   #7  
labman
Dogs Expert
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,600
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
I stand by my original post, but after your second one, I am not sure there is a problem. Anytime a circuit has a load, there will be a voltage between the neutral and ground. Where there is a voltage, given a path through your meter, there will be an amperage. While you are waiting, why not check some of your other circuits?
  Reply With Quote
 
     
 
 
Old Mar 23, 2007, 09:27 PM   #8  
tkrussell
Electrical & Lighting Expert
tkrussell is offline
 
Join Date: Jan 2005
Posts: 4,555
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
Sorry, but I do not understand what "Where do I find a GFI that is'nt a must trip at 7ma?" means.

Just a few other questions:

Exactly where is this current being measured and with what type of instrument?

Why is it perceived that there is a problem with a current flow from the neutral of the DW to ground?

How is it determined that the current is from the DW?

Is there voltage measured between this neutral and ground?

A GFI will not detect a ground fault from a neutral to ground potential difference, unless there is a connection problem with the neutral. An equipment ground is irrelevant to the operation of a GFI. A GFI only trips if the current flowing in the hot is different that the neutral.
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
gard pond leakage RAJUMATHE Construction 1 Mar 4, 2007 02:19 PM
DC Currents marinegurl Physics 2 Mar 1, 2007 06:22 AM
Water Heater Leakage channtas28 Plumbing 1 Nov 12, 2006 11:49 PM