    How to wire pendant lights in tandem
    I have three pendant lights that I am installing over a counter, these are low voltage lights I believe because they have two black wires and a groud wire. I alread have a wire coming from the light switch which has a black, white and ground wires. How do I connect these three pendant lights in tandem to this light switch.

    Thanks

    Mike
    [email protected]
    donf's Avatar
    donf Posts: 5,679, Reputation: 582
    Printers & Electronics Expert
     
    #2

    Sep 12, 2011, 01:42 PM
    First: Is the switch the power source for the existing lights?

    Check the switch and see if both the White and Black are connected to the screws on the switch. If they are, then this is a switch loop and it will not supply you with the needed Neutral / Return for the circuit.

    If the switch outlet has a continuous or spliced white that is not connected to the switch and Black connected to both the top and bottom screw of the switch, then the White would be a true Neutral and the Black would be the supply to the fixture.
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #3

    Sep 12, 2011, 03:35 PM
    these are low voltage lights I believe
    Believing isn't good enough. You have to know.
    If they are low voltage there will be a transformer with them.
    mthomason's Avatar
    mthomason Posts: 3, Reputation: 1
    New Member
     
    #4

    Sep 12, 2011, 03:41 PM
    donf;

    I checked the switch in the kitchen, the one switch that controlled the trac lighting where I'm putting the pendant lights has a black, white and red wires going into the back of the switch. There is also a white wire that is connected to the ground wire and screw. Also there is a black wire attached to the right lower screw on the switch. There is another switch in the laundry room that controlled the trac lights so they could be turned on when coming in through the garage
    As I stated this switch controlled the trac lighting that I just took down. I put up three pendant lights that have two black wires each, I'm wondering how do I connect the 12/2 wire coming from the switch to the three pendant lights to be able to turn them on with this single switch.

    Thanks

    Mike
    mthomason's Avatar
    mthomason Posts: 3, Reputation: 1
    New Member
     
    #5

    Sep 12, 2011, 03:48 PM
    donf

    The black wires coming from the pendant lights, one of them has the ridges on it and the other one is smooth... hope this helps more

    Mike
    Tfc2008's Avatar
    Tfc2008 Posts: 1, Reputation: 1
    New Member
     
    #6

    Sep 22, 2012, 09:02 AM
    I put together the wires my light is on and OK but my switch in kitchen don't work I can't put the light out
    shuntripper's Avatar
    shuntripper Posts: 180, Reputation: 8
    Junior Member
     
    #7

    Sep 22, 2012, 09:25 AM
    Quote Originally Posted by mthomason View Post
    Donf;

    I checked the switch in the kitchen, the one switch that controlled the trac lighting where I'm putting the pendant lights has a black, white and red wires going into the back of the switch. There is also a white wire that is connected to the ground wire and screw. Also there is a black wire attached to the right lower screw on the switch. There is another switch in the laundry room that controlled the trac lights so they could be turned on when coming in through the garage
    As I stated this switch controlled the trac lighting that I just took down. I put up three pendant lights that have two black wires each, I'm wondering how do I connect the 12/2 wire coming from the switch to the three pendant lights to be able to turn them on with this single switch.

    Thanks

    Mike
    Get a voltage tester,

    Both switches controlled the track lights? You have two three way switches controlling the old track lights. Each switch has a black screw on it, one of the switches' black screw will always be hot no matter what position either switch is in, leave that switch (call it A)alone and go to the other one (B) . Switch B's black screw is the switch leg, no matter what color wire was attached to it, this is the (hot)wire that goes up to the fixture.
    The new (pendant) fixtures MUST be 120V fixtures to connect them directly to the wire from the switch, all fixtures have a sticker saying what wattage/volt is maximum recommended for the lamp what does it say? What lamp is in the pendants will tell you also, do they say MR16 on them? MR16 lamps come in both 12V and 120V, They are not interchangeable but they ARE usually marked on the lamp itself

    Note: lamp means the bulb,tube,etc. to electricians
    shuntripper's Avatar
    shuntripper Posts: 180, Reputation: 8
    Junior Member
     
    #8

    Sep 22, 2012, 09:29 AM
    Quote Originally Posted by Tfc2008 View Post
    I put together the wires my light is on and ok but my switch in kitchen don't work I can't put the light out
    Did you change anything at either the switch in the kitchen or the switch by the garage?

Not your question? Ask your question View similar questions

 

Add your answer here.


Check out some similar questions!

Wiring indoor halogen lights - tandem [ 4 Answers ]

I have two halogen pendant lights to one switch. One light will not work. I replaced the transformer and no luck. My electrical tester is positive on the working light when the switch is on but not on the non working light. When the switch is the tester is positive on the bad light. What is wired...

Pendant light with single wire and metal sheath [ 0 Answers ]

I have two pendant lights hanging by a cord consisting of a single wire held in a metal sheath. The wire attaches to the wire in the ceiling, and the sheath twists off and attaches to the other wire in the ceiling. It was working before, but I dismantled it to replace the shade. The halogen bulb...

Track Lighting: 6 pendant lights/4 sections of track 2 lights not working? [ 4 Answers ]

Hi, Here is the situation. Two light bulbs blew. Our handy man told us that when you replace the bulbs 12v that you can not touch them or they will keep blowing. So we used gloves and changed the two blown bulbs. Voilą! Light. About 3 days later the first one blew again and then the...

Need to wire a pendant light with 100 watt bulb. Do I use 12, 14 or 16 gauge wire? [ 1 Answers ]

I want to rewire a floor lamp with 100 W bulb. Do I use 12, 14 or 16 gauge wire?

Wiring three pendant lights [ 2 Answers ]

I am trying to wire in three pendant light fixtures into our new home above the breakfast bar. There are three junction boxes already wired in when we bought the house, but no lights. In the first two boxes there are two sets of wires coming out two black gromets. In each set of wires there is a...


View more questions Search