    How do I splice the wires in the attic to put a light and a plug socket in the attic
    How do I splice wires in the attic to install a plug socket
    mcad's Avatar
    mcad Posts: 12, Reputation: 3
    New Member
     
    #2

    Jan 18, 2010, 06:29 AM
    If the attic is unfinished, odds are there are several junction boxes in there. If you are using a light that is going to be on a pullchain, then you need to find a hot and neutral in one of the junction boxes to take to the light and the receptacle. If it is going to be switch operated then you need to run the hot and neutral to the switch, and run a line to the light. The two neutrals will just tie together in the switch box and not go to the switch. The hot feeding the switch will go to one screw on the switch and the other wire (switch leg which should always be black) will go to the other screw on the switch.
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #3

    Jan 18, 2010, 06:56 AM

    I want to re-affirm that any splices must be contained in a junction box with a cover, and must be accessible.
    mcad's Avatar
    mcad Posts: 12, Reputation: 3
    New Member
     
    #4

    Jan 19, 2010, 05:30 PM
    Yes good call tk. And the light itself needs to mount to a box also.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Can I plug my electric oven into a normal plug socket? [ 2 Answers ]

Can I plug my electric single oven into a normal plug socket?

Heat from a light fixture (in attic) [ 5 Answers ]

Hi. I am laying down insulation in my attic. Can insulation be placed directly over the light fixture box?. one of those ocatgon boxes? Does heat emit from those? Into the attic and cause the underside of my roof to heat up?. How can I cover these boxes? Do I cover with insulation? Thanks

Do I need derate my wires from basement to attic ? [ 1 Answers ]

I have a 200A service panel main in the basement. I'll be installing a subpanel Main lug in the attic with a dual pole 60A breaker in the basement main feeding this Attic new subpanel. Using a #6/3 romex wire from basement to attic (about 35 - 40 feet total wire length). Along with this #6/3...

How to remove housing for light without attic access [ 4 Answers ]

I am planning to replace an existing ceiling light fixture with a recessed light. To put in the recessed light housing I need to remove the existing housing. But the problem is that I do not see any screws in the housing that I can unscrew. Probably this housing is connected to a joist but I do not...


View more questions Search