Home > Home & Garden > Electrical & Lighting   »   Hot/Ground Reversed

 
Thread Tools Search this Thread Display Modes
Question
 
 
#1  
Old Mar 25, 2006, 06:59 PM
tstevens83
New Member
tstevens83 is offline
 
Join Date: Mar 2006
Posts: 6
tstevens83 See this member's comment history on his/her Profile page.
Hot/Ground Reversed


Can you have lights and outlets coming from two circuits (i.e. two breakers from the main box)?

Also how do you reverse the ground and hot wire?

I am wanting to move a light switch... I went to the breaker box and turned off the power to that circuit. I proceeded to disconnect the light switch and I got a spark!! Boy was I surprised. After I completely disconnected the switch, I turned the breaker back on and tested the wires to see which one was the power, which one was the light, and which one went on to other lights and outlets. The wire going to the remaining lights and outlets, the ground tested hot!!

Also when I completely disconnected the switch, lights went out on another circuit. However, not all of the other circuit was affected. It seems two lights (3-way switches) and two outlets. The two outlets tested as having the hot/ground reversed. If the lights are turned off, the outlets go dead, as does the first wire that surprised me. If I turn any of the 3-way switches on, the grounds on the outlets all turn hot. The grounds at the 3-way switches test hot. Also the lights are not bright, they are dim.

I think those are all the facts as far as I can tell.

Reply With Quote
 
     

Answers
 
 
Old Mar 26, 2006, 04:09 AM   #2  
Senior Electrical & Lighting Expert
tkrussell is offline
 
tkrussell's Avatar
 
Join Date: Jan 2005
Posts: 5,817
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
There seems to be definite mis-wire someplace.Each circuit will need to be traced from the breaker panel to each and every outlet, switch , and junction box to find where sombody has both circuits connected together, and have reversed the hot and, when you say ground, I assume you mean the white wire, which is neutral or grounded, not ground.

If both circuits are on the same phase, then connecting both somewhere by accident will not trip any breakers, but give you a double feed like you found.

This is why we electricians test each wire before we touch it, even if we shut a breaker off, because the breaker may fail and not open, or in the rare case that two circuits got connected together.

Again, trace each circuit and check each connection poit, you will find where two circuits got connected together and the hot and neutral got reversed.
  Reply With Quote
 
     
 
 
Old Mar 26, 2006, 07:32 PM   #3  
New Member
tstevens83 is offline
 
Join Date: Mar 2006
Posts: 6
tstevens83 See this member's comment history on his/her Profile page.
Thank you for your respnose.

I actually did mean ground as in the bear copper wire... that's why I was surprised. How does the bear copper wire become hot? When I test the wires for Voltage... it will only read 120volts when the ground wire is tested.

When I closed the circuit by completing the circuit... all outlets check OK and lights work fine.

I will try to trace the wiring... any hints on how the best way to approach the tracing?
  Reply With Quote
 
     
 
 
Old Mar 27, 2006, 02:26 AM   #4  
Senior Electrical & Lighting Expert
tkrussell is offline
 
tkrussell's Avatar
 
Join Date: Jan 2005
Posts: 5,817
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
What you have with the actual equipment ground being energized is very dangerous, and needs to be correctly as soon as possible.

These circuits need to be shut off until wired correctly.

Tracing has no short cuts, start at the panel and follow the cable to each box it enteres, open the box and check the connections until the miswire is found.


Now that I look back, you say you test between the hot and ground, and get 120 volts, this is normal. What do you get if you test between the hot and neutral9 white wire)?
  Reply With Quote
 
     
 
 
Old Mar 29, 2006, 04:32 PM   #5  
New Member
tstevens83 is offline
 
Join Date: Mar 2006
Posts: 6
tstevens83 See this member's comment history on his/her Profile page.
I get zero volts between the hot and neutral.

When I reconnect the wires, the ground is no longer energized.
  Reply With Quote
 
     
 
 
Old Mar 29, 2006, 04:59 PM   #6  
Senior Electrical & Lighting Expert
tkrussell is offline
 
tkrussell's Avatar
 
Join Date: Jan 2005
Posts: 5,817
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
The circuit has an open neutral, which means the hot is at the the box you are testing, but the neutral (white) wire is broken or otherwise disconnected somewhere in the circuit.

Troublingshooting this means that the cable must be traced to each box, outlet, device, back to the panel if necessary, to find where the neutral wire has been broken or lost connection with the remaining circuit.

The neutral is the "return" for the circuit. The bare wire is not hot, but another, or supplemental return, this is why when you test from the hot to bare you read voltage.
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
Problem with reversed polarity on outlets
(1 replies)
Hot Ground/ Reverse
(5 replies)
Getting rid of ground ivy
(2 replies)
Hot Ground
(2 replies)
Hot and Ground Reversed
(1 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 08:11 PM.