Question
 
 
#1  
Old Jul 24, 2006, 11:03 AM
ToddP
New Member
ToddP is offline
 
Join Date: Jul 2006
Posts: 4
ToddP See this member's comment history on his/her Profile page.
Hot Ground/ Reverse

I have been struggling with an electrical problem for a while now:


I spliced into an electrical line in the basement to create an outlet. I wired everything perfect using experience and a home depot manual.

I kept getting a hot/ground reverse after purchasing several testers.

Then it would work great and then it would not. I finally figured out it was on the same circuit as several other fixtures.

I figured what I thought to be the culprit was our light out front...when the outlet I put in was working the light was not. I tested the light and it read Hot Neutral reverse.

I took apart the light pole and completely rewired it and it no longer had any problems. I went back to the outlet in the basement and it is still HOT / Ground Reverse???

It only has this problem when the power to the out front light is turned off....it works fine when it is turned on??

Sorry for the long post but I figured with more details someone could help me?

Reply With Quote
 
     

Answers
 
 
Old Jul 24, 2006, 02:18 PM   #2  
tkrussell
Electrical & Lighting Expert
tkrussell is offline
 
Join Date: Jan 2005
Posts: 4,555
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
The best advice I can offer is to follow this circuit back to the panel and start over from there. Trace and open each box, outlet, light, switch, etc. looking for the hot (black) and ground reversed.

Test each location , and make changes as necessary as you go out further on the circuit. Somewhere you should find a problem and all should be fine beyond that point.
  Reply With Quote
 
     
 
 
Old Jul 24, 2006, 05:50 PM   #3  
ToddP
New Member
ToddP is offline
 
Join Date: Jul 2006
Posts: 4
ToddP See this member's comment history on his/her Profile page.
when you say ground are you taliking about neutral? Do you think it coould be a neutral not connected somewhere? Should I check the connection to the box?

Thanks for the help
  Reply With Quote
 
     
 
 
Old Jul 25, 2006, 01:10 PM   #4  
tkrussell
Electrical & Lighting Expert
tkrussell is offline
 
Join Date: Jan 2005
Posts: 4,555
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
No I mean the ground, since you state the tester indicates reversed Hot & Ground. no I dont think something is not connected at all,I think someplace the wiring is reversed, or touching .

Yes start at the circuit breaker or fuse panel, and check each point of connection on the circuit until you find a problem.
  Reply With Quote
 
     
 
 
Old Jul 25, 2006, 01:18 PM   #5  
ToddP
New Member
ToddP is offline
 
Join Date: Jul 2006
Posts: 4
ToddP See this member's comment history on his/her Profile page.
Thanks TK, I will give it a shot and let you know how it turns out.
  Reply With Quote
 
     
 
 
Old Jul 25, 2006, 07:31 PM   #6  
ToddP
New Member
ToddP is offline
 
Join Date: Jul 2006
Posts: 4
ToddP See this member's comment history on his/her Profile page.
found out the wire I spliced into was a direct line from a light switch to outside light. They basically had 2 hot wires going to the light, hot and neutral. I fixed it but now when I turn off the switch upstairs the outlet goes out? I probably need to find another source.
Thanks again for the help TK
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
Reverse Mortgages DAVE231 Mortgages 5 Oct 12, 2006 05:34 AM
Ceiling Fan in Reverse dsciore Electrical & Lighting 3 May 31, 2006 08:36 AM
Hampton Bay Reverse Switch r shivers Electrical & Lighting 1 May 7, 2006 03:58 PM
Reverse Button BriRogers Electrical & Lighting 2 Feb 21, 2006 06:46 PM
Hot/Ground reverse on GFI receptacle helpinghand Electrical & Lighting 3 Jul 6, 2005 02:17 PM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 01:58 AM.

Content Relevant URLs by vBSEO 3.0.0 RC6 © 2006, Crawlability, Inc.