New Member
|
|
Aug 6, 2010, 06:45 AM
|
|
I have connected the light ceiling fixture but the light remain on cannot switch off
I have two black wires, one red, one wihite out of the box. I have connected the two blacks with the black fixture, and white with the white fixture wires. The red is not connected. The light (florescent U-tube light) comes on, but stays on, regardless of the switch being in the on or off position, what have I done wrong? Please help
|
|
|
Printers & Electronics Expert
|
|
Aug 6, 2010, 10:00 AM
|
|
More than likely you have just wired around the switch loop.
If a switch loop is present, you should find two cables in the ceiling. On will provide the power source and the other will provide the switch loop to the wall switch and back.
There is an alternative method of using a three wire to bring the power to the wall switch and then continue on to the device. In that case there would only one cable in the overhead.
Would you please pull the switch out and let me know what wires are connected to the switch.
|
|
|
Electrical & Lighting Expert
|
|
Aug 6, 2010, 10:17 AM
|
|
Sounds like the red was being used as the switched wire.
How was the old fixture hooked up?
|
|
|
New Member
|
|
Aug 6, 2010, 11:15 AM
|
|
Originally Posted by stanfortyman
Sounds like the red was being used as the switched wire.
How was the old fixture hooked up?
I didn't check that in my haste to connect the new one
|
|
|
Printers & Electronics Expert
|
|
Aug 6, 2010, 12:54 PM
|
|
On one of the white cables in the ceiling, is there black tape on it or any color tape? If there is, then do not follow the procedure given below.
What I expect is that the Black carrying the source power was connected to the red.
The red is then connected to the Black on the light fixture.
The White with the source power connects to the White from the fixture.
Switches do not use Neutral, unless there is a pilot light on the switch.
|
|
|
Home Improvement & Construction Expert
|
|
Aug 6, 2010, 02:11 PM
|
|
Look again, unless you have individual wires pulled in conduit, you can't have two blacks, one red and one white. You can have two blacks, one red and two whites. Must have missed a white. Pull switch and tell us what wires are connected to switch.
|
|
|
New Member
|
|
Aug 8, 2010, 03:13 PM
|
|
Originally Posted by hkstroud
Look again, unless you have individual wires pulled in conduit, you can't have two blacks, one red and one white. You can have two blacks, one red and two whites. Must have missed a white. Pull switch and tell us what wires are connected to switch.
You're right 2blacks, 2whites 1red.
One red, one black is connected to the switch
|
|
|
New Member
|
|
Aug 8, 2010, 03:17 PM
|
|
Originally Posted by donf
On one of the white cables in the ceiling, is there black tape on it or any color tape? If there is, then do not follow the procedure given below.
What I expect is that the Black carrying the source power was connected to the red.
The red is then connected to the Black on the light fixture.
The White with the source power connects to the White from the fixture.
Switches do not use Neutral, unless there is a pilot light on the switch.
There is no tape on the white or any wires. I have 2white, 2blacks, 1 red coming from the box, the light fixture has one white, one black.
The switch has a black and red going to it So what is the right connection that I should be doing?
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
Adding a light kit to ceiling fan w/ light & dimmer switch
[ 6 Answers ]
I would like to add a light kit to a ceiling fan(cannot find a name on it) that is currently hooked and working up in our family room - since we moved in 6 years ago (house was built in 1991).
I would like this to operate like our bedroom ceiling fan (which already has a light attached) and...
How to install and power a Ceiling Light from a light switch?
[ 1 Answers ]
I need to install a ceiling light in our bedroom. I have a single light switch and four outlets. One of the outlets is operated by the light switch. I have the following wires coming into the light switch box: three white wires/capped, three copper ground, three black/capped with a fourth pig...
Bathroom Light and Fan connected at switch need to separate
[ 3 Answers ]
All of our bathrooms have the vanity light fixture and the ceiling exhaust fan connected to one switch, so we can never just have the light or just the fan on. They are ALWAYS on together. We want to put them on sperate switches, but when we opened the face plate we found to white wires bound...
Light Switch and Fixture
[ 1 Answers ]
Bought a 72 Mobile Home.
Want to install new hall light. From box comes B & W(B) light Switch wires. Main Feed w/ B & W & Ground. than 2nd set B, W & Ground.
The circuit breaker for this powers the following Kitch & LR & BR light as well as the Hall light & switch. Im think that the...
View more questions
Search
|