Home > Home & Garden > Electrical & Lighting   »   gfci spa panel tripping

 
Question Tools Search this Question Display Modes
Question
 
 
#1  
Old Dec 21, 2005, 01:06 AM
sunworshipper
New Member
sunworshipper is offline
 
Join Date: Dec 2005
Posts: 1
sunworshipper See this member's comment history on his/her Profile page.
gfci spa panel tripping

I just installed a spa with 4 wires. The house is old and while the neutral & ground bus bars are separate in the spa panel, they are all on the same bar in the main panel. Do I need to install a ground rod by the spa panel to keep the gfci from tripping? (instead of running the ground back to the main panel neutral/ground bus bar)

Reply With Quote
 
     

Answers
 
 
Old Dec 21, 2005, 11:14 AM   #2  
jamlove
Junior Member
jamlove is offline
 
jamlove's Avatar
 
Join Date: Jun 2005
Location: Seattle, WA, USA
Posts: 66
jamlove See this member's comment history on his/her Profile page.
ground fault

Hi,
It sounds like either the wiring is incorrect, or you have a problem with the spa equipment. Something is grounding out (shorting out) that causes the GFCI to trip.

I'd stay out of that water until you can get the equipment checked by an electrician...

Ground and Neutral are on the same bus in my panel, no problem there. Double-check that you've wired correctly, but maybe corrosion has caused one of your pumps or motors to ground-fault?

Good luck, j
  Reply With Quote
 
     
 
 
Old Dec 21, 2005, 03:25 PM   #3  
tkrussell
Electrical & Lighting Expert
tkrussell is offline
 
Join Date: Jan 2005
Posts: 4,555
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
First of all, do not install a ground rod. This will not solve your problem with the GFI, and is a code violation. Too much detail to explain here why,please take my word for it.

The GFI breaker has a neutral wire coming off of it that must go the the neutral bar in the panel. The white load wire, from the spa must connect to the screw terminal under or near this white wire on the GFI breaker. many times this white wire from the load is connected improperly. Check to be sure this is done correctly. The terminal for the white load wire on the breaker sometines is hard to see. I know because I have missed it my self. This is a popular reason for GFI to trip on a new spa.

The neutral and equipment ground are to be connected at the main panel, only, and separate at any subpanel, so thats correct.

Check the GFI breaker to be sure the load white is connected properly, I bet that is the problem.
  Reply With Quote
 
     
 
 
Old Dec 21, 2005, 04:43 PM   #4  
labman
Dogs Expert
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,600
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
There are 2 people here you want to follow their instructions exactly, tkrussel and Tom in plumbing. Before they came, I didn't realize how little I knew.

Your question sounded like it should work, but I didn't know what to tell you to look for.
  Reply With Quote
 
     
 
 
Old May 15, 2007, 08:46 AM   #5  
Stratmando
Ultra Member
Stratmando is offline
 
Stratmando's Avatar
 
Join Date: May 2007
Location: Florida Keys
Posts: 3,827
Stratmando See this member's comment history on his/her Profile page.Stratmando See this member's comment history on his/her Profile page.
Unplug or disconnect spa motor, GFI doesn't trip? Change motor.
Repeat for other features. blower etc...
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
Window Air Conditioner & Circuit Tripping adancingirl Heating & Air Conditioning 7 Jul 23, 2006 11:44 AM
Window mount AC tripping circuit breaker the_nite_owl Electrical & Lighting 4 Jul 13, 2006 02:03 PM
Gfci diglajo Electrical & Lighting 1 Apr 14, 2006 11:06 AM
a/c power breaker tripping kjordan Heating & Air Conditioning 2 Jul 26, 2005 05:24 AM
GFCI on breaker panel trips, 3 way, how to find the problem? lionfoxx Electrical & Lighting 1 Jul 22, 2005 06:26 AM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 11:30 PM.

Content Relevant URLs by vBSEO 3.0.0 RC6 © 2006, Crawlability, Inc.