Old Mar 23, 2007, 10:01 AM
michaelc
New Member
michaelc is offline
 
Join Date: Mar 2007
Posts: 2
michaelc See this member's comment history on his/her Profile page.
GE cooktop wiring - 1957 change to 2007

I just removed a 1957 GE electric cooktop and installed the a new GE cooktop model#JP328WKWW. I got three wires come from breaker 2 black and 1 white. I use the volt meter to touch each black to the white wire, both gives me 120V. I think the 2 black is hot wires and the white one is neutral. The new cook top is for 208/240V and having 3 wires red, black, and bare wire. How should I connect the old wires to be able present a 240V to the new cooktop? Thanks

**update**
I just ask a friend, he told me I should first check the breaker and make sure the two black wire that comming from breaker is attach to the breaker and the white wire is attach somewhere to the ground. If the checking resault is same as he think, then I can connect one black to the red at cooktop and the other black to the black at cooktop and finally connect the white one to the bear wire as ground. If nothing happened this should give me a 240V output to the cooktop. I will try it tonight, if anyone has any comment for any possible suggestion, please kindly let me know. Thanks.

Michael

Reply With Quote
 
     

Answers
 
 
Old Mar 23, 2007, 05:14 PM   #2  
tkrussell
Electrical & Lighting Expert
tkrussell is offline
 
Join Date: Jan 2005
Posts: 4,481
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
The advice you received is correct, with one thing to check.

If the white is connected to the neutral bar in the panel, which is also connected to the equipment ground at the panel, then the white may be used as the equipment ground, simply label it as ground with green tape at both ends.



A simple method of checking if the neutral is connected to ground at the panel is they will be only if the main breaker is located in this panel.

If not, then the white wire must be removed from the neutral bar, relocated to the equipment ground bar, and tape both ends green as before.
  Reply With Quote
 
     
 
 
Old Mar 26, 2007, 12:20 PM   #3  
michaelc
New Member
michaelc is offline
 
Join Date: Mar 2007
Posts: 2
michaelc See this member's comment history on his/her Profile page.
Quote:
Originally Posted by michaelc
I just removed a 1957 GE electric cooktop and installed the a new GE cooktop model#JP328WKWW. I got three wires come from breaker 2 black and 1 white. I use the volt meter to touch each black to the white wire, both gives me 120V. I think the 2 black is hot wires and the white one is neutral. The new cook top is for 208/240V and having 3 wires red, black, and bare wire. How should I connect the old wires to be able present a 240V to the new cooktop? Thanks

**update**
I just ask a friend, he told me I should first check the breaker and make sure the two black wire that comming from breaker is attach to the breaker and the white wire is attach somewhere to the ground. If the checking resault is same as he think, then I can connect one black to the red at cooktop and the other black to the black at cooktop and finally connect the white one to the bear wire as ground. If nothing happened this should give me a 240V output to the cooktop. I will try it tonight, if anyone has any comment for any possible suggestion, please kindly let me know. Thanks.

Michael
Thank you tkrussell, it works with 240V output now.
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
How to change wiring on phone jack for DSL mattieo Landline Phones 3 Aug 10, 2007 04:40 AM
1957 Curse of the Demon Adigiorgio Movies 1 Feb 28, 2007 02:40 PM
Change Hot tub heater wiring scottyikon Electrical & Lighting 8 Feb 25, 2007 08:55 PM