Home > Home & Garden > Electrical & Lighting   »   Wiring for a dustless unit

 
Question Tools Search this Question Display Modes
Question
 
 
#1  
Old Apr 10, 2007, 03:20 AM
Droff
Junior Member
Droff is offline
 
Join Date: Jan 2007
Posts: 38
Droff See this member's comment history on his/her Profile page.
Wiring for a ductless unit

I have a 15KBTU mini split unit and the data calls out for 14/3 wire to run 220V, 15 Amps to the condensor. This seems kind of light to me but this is what is called for. My run is going to be around 90'-100', should I use heavier wire, say 12/3?
Thanks.

Reply With Quote
 
     

Answers
 
 
Old Apr 10, 2007, 06:27 AM   #2  
ballengerb1
Home Repair & Remodeling Expert
ballengerb1 is offline
 
Join Date: Dec 2006
Location: Wheaton, Illinois, USA
Posts: 8,427
ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.
It won't hurt to move up to 12/3 or even 10/3 for future equipment. They don't normally expect a 100 ft run, too much line drop.
  Reply With Quote
 
     
 
 
Old Apr 10, 2007, 11:01 AM   #3  
JackT
Full Member
JackT is offline
 
Join Date: Apr 2007
Location: South Carolina
Posts: 258
JackT See this member's comment history on his/her Profile page.
Most 15,000 btu/hr, 230 volt mini split condensing units only use about 8 amps. 14/3 is normally rated at 15 amps so 14/3 should work fine but it never hurts to go bigger.
  Reply With Quote
 
     
 
 
Old Apr 11, 2007, 09:09 AM   #4  
Droff
Junior Member
Droff is offline
 
Join Date: Jan 2007
Posts: 38
Droff See this member's comment history on his/her Profile page.
I'm going to go with 12/3 and a 20 amp breaker. Do I need to put a disconnect switch next to the outdoor unit or am I okay with just the breaker inside the house?
Thanks.
  Reply With Quote
 
     
 
 
Old Apr 11, 2007, 09:13 AM   #5  
ballengerb1
Home Repair & Remodeling Expert
ballengerb1 is offline
 
Join Date: Dec 2006
Location: Wheaton, Illinois, USA
Posts: 8,427
ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.
That would be the safe way to do the installation. You could just install a sub panel. Is this a garage, barn, work area being connected to a home?
  Reply With Quote
 
     
 
 
Old Apr 11, 2007, 11:53 AM   #6  
JackT
Full Member
JackT is offline
 
Join Date: Apr 2007
Location: South Carolina
Posts: 258
JackT See this member's comment history on his/her Profile page.
Electrical code requires a disconnect means within sight and readily accessible. NFPA 440-14
  Reply With Quote
 
     
 
 
Old Apr 11, 2007, 01:16 PM   #7  
Droff
Junior Member
Droff is offline
 
Join Date: Jan 2007
Posts: 38
Droff See this member's comment history on his/her Profile page.
This is for a bonus room in my attic. I installed a sub panel in the room and I'm going to wire the mini-split off of it. I think I'd just go with a disconnect switch/box and nothing more than that. I don't think I need another breaker or anything like that within sight and readily accessible.
Thanks.
  Reply With Quote
 
     
 
 
Old Apr 11, 2007, 02:27 PM   #8  
JackT
Full Member
JackT is offline
 
Join Date: Apr 2007
Location: South Carolina
Posts: 258
JackT See this member's comment history on his/her Profile page.
Thats your option but, if you ever decide to sell your home and need a electrical inspection done, it will be a electrical code violation. It also helps the service technician when servicing the unit and provides a way to shut the unit off in case of an emergency if no one is at home.
  Reply With Quote
 
     
 
 
Old Apr 12, 2007, 01:46 AM   #9  
tkrussell
Electrical & Lighting Expert
tkrussell is offline
 
Join Date: Jan 2005
Posts: 4,555
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
A circuit breaker in the panel is required, and a switch at the outdoor unit will suffice.
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
Outside unit doesnt come on when thermostat turns inside unit on so no heat? amcat80 Heating & Air Conditioning 1 Oct 7, 2007 06:04 PM
A/C unit to thermostat dona1120 Electrical & Lighting 0 Mar 28, 2007 02:28 PM
heating unit ironkev Heating & Air Conditioning 1 Mar 26, 2007 09:21 AM
replacement of electric unit with gas unit in mobile home vcavina Heating & Air Conditioning 2 Jan 5, 2007 12:57 PM
old window unit gjscott67 Heating & Air Conditioning 1 Sep 4, 2006 10:31 AM