Thread Tools Display Modes
Question
 
 
#1  
Old Jul 11, 2006, 12:58 PM
kaluda1
New Member
kaluda1 is offline
 
Join Date: Aug 2005
Posts: 7
kaluda1 See this member's comment history on his/her Profile page.
Voltage Drop

I have a 20 amp breaker;there are a total of 7 receptacles on this circuit with a 15 amp GFI on the first receptacle.

The first 5 receptacles in line work fine, the last two receptacles which are approximately 70 feet from the 5th receptacle flip the 15 amp GFI off when plugging in a drill. I have immeasurable power making a drill barely turn. THe complete run is approximately 140 feet. Why do the first 5 work and the last two do not? WHAT is the problem.

Thanks Bob

Reply With Quote
 
     

Answers
 
 
Old Jul 11, 2006, 02:48 PM   #2  
Senior Electrical & Lighting Expert
tkrussell is offline
 
Join Date: Jan 2005
Posts: 4,723
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
I think you have a loose connection causing this problem. Check the last outlet in the circuit that is working, and the first outlet that is not. Look for the type of connection to each outlet called "Stab in the back" or "Quik-Wire", "Wiz-Wire" , etc.

This is done by stripping each wire about a half inch, and pushing the straight wire into a hole on the back of the device. These connections are popular for causing loose connections.

To change over to the standard wrap around the screw connection, you will need to gently pull and twist the wire out of the hole. Sometimes there is a small rectangle slot near the hole to insert a very small screwdriver to release the wire from the hole. Check to be sure any loose connection did not cause heat the damaged the outlet.

If these connections do not exist or are not the problem, then there may be a bad or loose splice, but my bet is on the quik wire method being the culprit
  Reply With Quote
 
     
 
 
Old Jul 11, 2006, 03:18 PM   #3  
New Member
kaluda1 is offline
 
Join Date: Aug 2005
Posts: 7
kaluda1 See this member's comment history on his/her Profile page.
Thanks, that is what it was'
OUt of curiosity where are you, your time appears to be 5-6 hours ahead of my California time. Thanks again.
  Reply With Quote
 
     


Thread Tools
Display Modes

 
Similar Sponsors

Similar Threads
Question Asker Forum Answers Last Post
9-8 drop? sujatha Plumbing 1 May 22, 2006 05:16 AM
voltage drop. is this normal? davidinmo Electrical & Lighting 2 May 17, 2006 06:35 PM
voltage drop H. Bunch Electrical & Lighting 2 Mar 23, 2006 05:53 AM
Voltage doubler labman Electrical & Lighting 1 Aug 23, 2005 03:20 PM
drop down bandit_38 Other Computers 2 Oct 9, 2003 11:01 PM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 07:17 AM.