    Can I splice tap the ground wire from sub pannel to the ground wire at the water line
    ColinD's Avatar
    ColinD Posts: 4, Reputation: 1
    New Member
     
    #2

    Jan 4, 2011, 01:14 PM
    I assume you are talking about supplemetary earthing and bonding of your plumbing.

    You should check your local electrical regulations in your county. If you are not sure call in your local electrical person.

    For the UK (should be similar in USA)...

    You should have a main earth bar in your fusebox (panel).

    You can run an earth cable from fusebox earth out to the cold copper pipe in your kitchen sink and bond it to the pipe so it is earthed (Use 6mm earth cable and put an earth tag on it).

    Another earth cable from fusebox earth out to the electric shower copper pipe in the bathroom, and bond it to the pipe so it is earthed. (Use 6mm earth cable and put an earth tag on it).

    You should also bond all your cold and hot water pipes together with a 6mm earth wire bond and tag under all sinks and baths.

    For safety... Electric showers should also have a 30mA RCD trip unit to power the shower, which will trip if an earth leakage current is detected.
    Current rating of this unit will depend on the wattage of the shower.

    Cheers ColinD
    donf's Avatar
    donf Posts: 5,679, Reputation: 582
    Printers & Electronics Expert
     
    #3

    Jan 4, 2011, 01:29 PM

    No.

    For a residence here in the U.S. the NEC requires the bonding of the Equipment Grounding Conductor to a point within 5' of the "Metal" water pipe, where it enters the building. The metal water pipe has to extend 10' into the ground.

    You are also required to have a supplemental grounding system by way of ground rods.

    There are also several other methods to set up a grounding system.

    At the Main Service Panel, you must use the "Main Bonding Jumper" to create the grounding conductor to Bond to the Neutral (or grounded conductor from the power company.)

    From the Main service panel to subpanel, you use a 4 wire feeder.

    2 hots, 1 neutral and one ground.

    At the subpanel, Neutral and Ground must be isolated from each other so do not use a main bonding jumper sat the subpanel.

    If the subpanel is in the same building, you do not need a supplemental grounding system. If the subpanel is in a remote building, you have to set up a supplemental grounding system.
    stanfortyman's Avatar
    stanfortyman Posts: 5,598, Reputation: 279
    Electrical & Lighting Expert
     
    #4

    Jan 4, 2011, 01:46 PM
    Quote Originally Posted by Pier66 View Post
    Can i splice tap the ground wire from sub pannel to the ground wire at the water line
    The other gave you some good information, but there is not enough detail here to give an accurate answer.

    What exactly are you asking? Why would you need to do this?

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Can I use a ground wire for a ground and live black or hot wire at the same time? [ 8 Answers ]

I only have 3 wires from my ceiling to connect to my fan/light, the black, white and bare ground. No problems setting up in this room to only one switch but I would like to have the duel fan/light switch in like in my other rooms without having to pull a wire from the ceiling down to the switch,...

Can I butt splice a main breaker ground wire to make it longer [ 9 Answers ]

The ground wire that comes from the meter to the main breaker is too short for the new box I want to install. Can I butt splice the ground to make it longer. This is the 4.0 ground and is about 18" short

Nec-covering of ground wire from the ground rod to the water pipecables [ 1 Answers ]

I installed a new service meter panel and ground rod. The ground rod is connected to the meter panel via a #4 copper wire to a water pipe located 10 feet away. Is is allowable to bury the #4 wire between the ground rod and water pipe to keep it from being a trip hazard and protect the wire? ...

Can you splice into an existing ground wire to add a receptacle? [ 2 Answers ]

Adding a receptacle with two wire system, can I splice into an existing ground wire to ground my neew receptacle?

What do I need to do to install the ground wire for my house on my copper water line? [ 1 Answers ]

Please help! I am a 27yr old new home owner of 2 years living in Alabama and my water pipes froze the other day, so after the whole hair dryer thaw out time, thinking I'd done enough research, I went and bought foam pipe insulation and installed it. When I was down there I was covering the part...


View more questions Search