    I have a 3 HP irrigation pump fed by a normal 240v service line from a relay activated by the irrigation controller. The pump uses 2 lines plus a ground. I have one extra conductor line running to the pump station.

    Is there a code acceptable way to use that line, and one of the pump lines to add a small heater to keep the pump from freezing, without changing the pump/relay function?

    Or, is my only option to plug in the heater or the pump but never both?

    Preferably, the new wiring would contain a thermostat so that the heater would only run when needed.
    stanfortyman's Avatar
    stanfortyman Posts: 5,598, Reputation: 279
    Electrical & Lighting Expert
     
    #2

    Jul 26, 2008, 05:58 PM
    What size is the circuit; wiring and breaker size?

    What kind of heater are you looking at?
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #3

    Jul 26, 2008, 07:13 PM
    While Stan's questions need to be answered, if the circuit wiring is of ample size one to run both, issue I see is the heat will only work when the pump is running.

    Another set of wires will need to be added for the heat, or the contactor will need to be relocated to the pump area, so the feeder can be converted to live constantly, and let the pressure switch control the pump contactor and the thermostat control the heat, again at the pump house/pit.

    Is is possible to move the contactor?

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

How to Prime irrigation pump [ 2 Answers ]

The installer put a Jet-Rite 2 well tank where the priming tee is. There does not seem to be anyplace where I can fill pump and piping with water. The pump has not been used in about 1 month and was unplugged. Now it needs to be primed and I don't know what to do! Can someone please help!

240V Heater Wiring [ 1 Answers ]

Is it safe to hard wire a 240v 15A Heater to a 30A 240V breaker? Are there any draw backs?


View more questions Search