#1  
Old Jul 11, 2007, 11:34 AM
tallguy
New Member
tallguy is offline
 
Join Date: Jan 2007
Posts: 16
tallguy See this member's comment history on his/her Profile page.
3 Questions about updating to a GFCI outlet

I recently attempted to update a basic 3-prong outlet to a GFCI outlet (so that I could connect a do-it-yourself, low-voltage, exterior lighting kit to this outlet). It seemed to work for the most part, but I have three issues of concern.

1) The breaker for this circuit (and this outlet seems to be the only thing on this circuit) is a 20 amp breaker. Is it OK to use a 15 amp GFCI outlet? The old outlet is rated for 15A.

2) There were two cables coming into the outlet box. One had all three wires (white, black, bare) connected to the old outlet. The other had the white and black wires taped off, and the bare wire connected to the outlet's ground terminal along with the bare wire from the first cable. What could be the point of this? I attached the new outlet in the same manner.

3) My three-prong tester indicated that the new GFCI outlet was installed correctly, and when I pressed the test buttons (on the tester and the outlet itself) the circuit was tripped. However, when I plugged in the old lamp that was always connected to this outlet, there was a spark and the circuit tripped, and even left a small, black char on the outlet! When I connected a fax machine to the outlet as another test it seemed OK.

Two caveats: The plug on the lamp was wired by the previous home owner. Also, the old outlet indicated reversed hot/neutral when tested. There was never a problem using the lamp wen it was connected to the old outlet.

That's a lot. Sorry to be so wordy. Thanks very much for any solutions.

Reply With Quote
 
     

Answers
 
 
Old Jul 11, 2007, 01:33 PM   #2  
tkrussell
Electrical & Lighting Expert
tkrussell is offline
 
Join Date: Jan 2005
Posts: 4,486
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
My answers are in bold:


1) The breaker for this circuit (and this outlet seems to be the only thing on this circuit) is a 20 amp breaker. Is it OK to use a 15 amp GFCI outlet? The old outlet is rated for 15A.

Yes.

2) There were two cables coming into the outlet box. One had all three wires (white, black, bare) connected to the old outlet. The other had the white and black wires taped off, and the bare wire connected to the outlet's ground terminal along with the bare wire from the first cable. What could be the point of this? I attached the new outlet in the same manner.

Probably the taped wires were to an old outlet or some other device that has been removed or abandoned.


3) My three-prong tester indicated that the new GFCI outlet was installed correctly, and when I pressed the test buttons (on the tester and the outlet itself) the circuit was tripped. However, when I plugged in the old lamp that was always connected to this outlet, there was a spark and the circuit tripped, and even left a small, black char on the outlet! When I connected a fax machine to the outlet as another test it seemed OK.

If it tripped the GFI, then tester did what it is intended to. If it triped the breaker, we got to figure out why.

Seems there is a short (ground fault) in the lamp, it should be checked and repaired.



Two caveats: The plug on the lamp was wired by the previous home owner.

Is the lamp worth fixing?

Also, the old outlet indicated reversed hot/neutral when tested. There was never a problem using the lamp wen it was connected to the old outlet.

Is the polarity correct now? Or is it still shows as reversed hot/neutral?
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
Updating Brick Fireplace GypsyWoman Interior Home Improvement 3 Mar 24, 2007 12:47 PM
220 Outlets & GFCI Questions JimV Electrical & Lighting 3 Feb 8, 2007 10:40 AM
Updating Printer Driver ranlas Windows 12 Mar 24, 2006 12:52 PM
Trouble Updating Records Individually andy5179 Internet & the Web 3 Aug 19, 2005 08:08 AM
Updating Mozilla traka Email 0 Mar 29, 2005 07:58 PM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 07:46 PM.

Content Relevant URLs by vBSEO 3.0.0 RC6 © 2006, Crawlability, Inc.