    Miles Quance's Avatar
    Miles Quance Posts: 1, Reputation: 1
    New Member
     
    #1

    Jan 10, 2007, 03:04 PM
    240v Electrical circuit testing
    I have replaced a celling light in my kitchen. The replacement light has a stainless steel casing, however the wiring circuit in the house has no earth at the celing, so I have not connected an earth. It has 2x black wires , 2x red wires ( switching & connected together ) & 1x black wire with a red stripe ( live ) I have connected these as required & the light functions as intended. I have an electrical testing screw driver ( type 140 . 220-240 volts ) which I have used to test the casing of the light. When I do the indicator lights very dimley. The parts are fine to touch. Why is this ? What does the tester indicate? What should I do? I have inspected the wiring again & found no problems. All of the wires in the casing are single insulated. Can anyone explain or offer any help please.
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #2

    Jan 10, 2007, 03:34 PM
    I am guessing you are located in the UK or some exotic place like that, by the 240 volt wiring and the word "earth".

    The indicator light may be dim because it is close to the hot wires inside the metal housing. Best to be sure there is no short by using a volt meter with test leads. You will need to make one lead long enough using some scrap wire so that one lead can reach a grounded( Earthed,) surface, such as a water faucet, sink, water pipe, or a earth terminal on a receptacle.

    Measure the volts across the fixture metal frame and earth, and you should find close to zero volts. If there is any significant volts, 30 or more, then there is a short to the metal frame.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

120V or 240V for heaters? [ 6 Answers ]

I apologize in advance for seeming daft :confused: , but I am still missing the 120V vs. 240V issue for small appliances such as room heaters. There seems to be an advantage of 240 V only when you may be pushing your circuit; I gather one can put twice as much wattage (e.g. heaters) on a 20A...

240V Halogen GU10 Mains on a 120V Circuit ? [ 5 Answers ]

I recently came across some GE 240V halogen bulbs in England, they are a GU10 type base and MR16 size/shape/type(?) bulb. They are not available in North America yet and having been available for some time in the UK and Europe, it doesn't look promising they will be on the market here anytime...

Lighting/electrical - is separate circuit possible? [ 3 Answers ]

I have lights in my house that have both a regular switch and a dimmer switch. A few days ago I used the regular switch to turn on the lights and it looked like a circuit breaker tripped and the lights went out. I checked the main box and no circuits were tripped... and I looked for a sub-panel...

Electrical Testing Screwdriver [ 1 Answers ]

How do you test electrical sockets with these. I have accidentally disconeda ring main, and need to test which socket is at fault

Outside GFI circuit - 15amp outlet on 20amp circuit [ 1 Answers ]

I need a better understanding of what I should do when setting up my new outdoor circuit. I've got a circuit that runs about 150 feet, so I'm installing 10g wire to allow for the voltage drop. I read in the Home Depot Electrical 123 book that I can have at most a 15amp circuit with 10g wire on...


View more questions Search