2-phase vs 3-phase degrees of seperation

At work we have 3-phase power. I understand the oscillations are 120 degrees apart.

At home I have 2-phase power. Are the oscillations 180 degrees apart? I understand the neutral on a 240v circuit should carry 0 as the phases cancel each other out.

My real question is that if we have a 2-phase motor powered by 2 phases of the 3-phase circuit at work, is the neutral again carrying 0 or would it carry some current because the 2 used phases are not 180 degrees of each other?

Reply With Quote
 
     

Answers
 
 
Old Aug 25, 2006, 08:01 AM   #2  
New Member
yokeman is offline
 
Join Date: Jul 2006
Posts: 7
yokeman See this member's comment history on his/her Profile page.
If the system is well balanced the neutral will carry little current. This is the way the power company likes it, but rarely the case. Any unbalance will cause a netural wire current flow.
  Reply With Quote
 
     
 
 
Old Aug 25, 2006, 08:25 AM   #3  
Senior Electrical & Lighting Expert
tkrussell is offline
 
tkrussell's Avatar
 
Join Date: Jan 2005
Posts: 5,824
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
You have single phase at home, it is called an Edison three wire system. Two hot legs are the one phase, the neutral is the center tap of the transformer, which divides the voltage in half.

If a 3 wire circuit is balanced there will be no current flow in the neutral.


A Single phase circuit off of a three phase with a neutral is always current carrying, never gets balanced.

You need all three hots with a neutral and each circuits to carrying the same load to see zero amps in a balanced three phase circuit.

The rotation is 360 deg on a true single phase service. A three phase is 120 deg apart.
  Reply With Quote
 
     
 
 
Old Aug 30, 2007, 11:14 AM   #4  
New Member
bijendra is offline
 
Join Date: Aug 2007
Posts: 1
bijendra See this member's comment history on his/her Profile page.
Quote:
Originally Posted by malibuclassic77
At work we have 3-phase power. I understand the oscillations are 120 degrees apart.

At home I have 2-phase power. Are the oscillations 180 degrees apart? I understand the neutral on a 240v circuit should carry 0 as the phases cancel each other out.

My real question is that if we have a 2-phase motor powered by 2 phases of the 3-phase circuit at work, is the neutral again carrying 0 or would it carry some current because the 2 used phases are not 180 degrees of each other?
NO CURRENT in nutral is not 0,the phasor sum of current in 2 phase is not 0...........
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login



Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes
Ask your question or search...



Similar Threads
Dioxane phase diagram
(1 replies)
What is a Phase I enviromental report?
(1 replies)
480 v 3 phase
(1 replies)
is this a phase?
(4 replies)
Phase 1 enviromential report
(0 replies)

Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page
Search this Thread

Advanced Search

Bookmarks





Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 11:55 AM.