Ask
    AOTO's Avatar
    AOTO Posts: 6, Reputation: 1
    New Member
     
    #1

    Sep 7, 2007, 08:39 AM
    Using 2 x 12 & plywood for girders
    I want to span a 10' space and was going to make the 2 x 12 & plywood style beam. I planned on making the beam 10'10" (130") and supporting it on each end with 5" (2 x 6 and 4 x 6) so that the 120" (10') was open. Should I be concerned with this breaking or sagging after reading about the LAL or other type of composite beam? What would they do in the old days? Or, am I going to be okay..
    glavine's Avatar
    glavine Posts: 895, Reputation: 87
    Senior Member
     
    #2

    Sep 7, 2007, 07:26 PM
    keep in mind this is my opinion, I think your fine with that span, however if inspected it wouldn't pass code.

    here something I do regularly, we build a lot of decks that span 10ft to a beam on almost every deck we do. We use 2x10s, and I've yet to see and saging, keep in mind the only load we have are decking boards and whomever is on the deck at that time,
    I don't know the load that is on your beam, that is to me the desiding factor whether this will be OK. If your nervous still about using that beam, just ask a structural engenineer and hell be able to tell you what you can use, most likely he'll have you use a microlamb beam.
    AOTO's Avatar
    AOTO Posts: 6, Reputation: 1
    New Member
     
    #3

    Sep 8, 2007, 07:47 AM
    Thanks for the heads up... I may go see somebody that would know. I am also putting up an attic truss.
    Flying Blue Eagle's Avatar
    Flying Blue Eagle Posts: 2,056, Reputation: 225
    Ultra Member
     
    #4

    Sep 8, 2007, 01:03 PM
    Real good answer GLAVINE! I WAS going to susgest the same .2x12 with 1/2" plywood glued both sides then nailed both sides with 16 penny cement coated nails . And span 10 ft. no problem . But what's above/ ,that's another think about. And how far apart are these beams going to be??
    AOTO's Avatar
    AOTO Posts: 6, Reputation: 1
    New Member
     
    #5

    Sep 9, 2007, 07:38 PM
    Quote Originally Posted by Flying Blue Eagle
    Real good answer GLAVINE !! I WAS going to susgest the same .2x12 with 1/2" plywood glued both sides then nailed both sides with 16 penny cement coated nails . and span 10 ft. no problem . but whats above/ ,thats another think about. and how far apart are these beams going to be ????

    It is for a 32' x 48' building. I have attic truss's that are spanning the 32 feet wide.
    The end door is the 10' span, I don't think it'll be bearing the weight. The other walls, the sides, are going to be holding up the truss's, there will be nothing in between. There are 2 doors on that side 8' and none on the other.
    skiberger's Avatar
    skiberger Posts: 562, Reputation: 41
    Senior Member
     
    #6

    Sep 9, 2007, 08:29 PM
    10' opening on the gable end side of a trussed building?

    No problem. Build your beam. It's not holding anything up so there's no load on it. Also you only need 2-2x6's under each end of the header. You don't have to overkill it with 5" supporting each side.

    A 3-2x12 beam w/ sandwiched plywood w/ 2 jack studs under each end supporting a ceiling and roof can clear span any where from 9"5" to 12"2" depending on building width and psf of snow load.
    Flying Blue Eagle's Avatar
    Flying Blue Eagle Posts: 2,056, Reputation: 225
    Ultra Member
     
    #7

    Sep 13, 2007, 09:25 PM
    AOTO, don't worry about the plyeood only being 8 FT. cut a piece 4 ft. long to finish length. It s the only way.:::"

Not your question? Ask your question View similar questions

 

Add your answer here.


Check out some similar questions!

Rafter damage/plywood vs boards [ 3 Answers ]

I have a 70 yr old house. It's 500 sq feet and I'm replacing the roofing. I have many damaged rafters from termites. Do I remove the boards to fix the rafters? I have only 3-1/2 feet of space in the attic. Also, do I use the new plywood for the roof or do I use the 1 x 8 tongue and groove redwood...

Tiling over plywood [ 2 Answers ]

:confused: Thank you for your answers;Clear-Mind-Web &Kstar4u, I can't seem to get my hands on the BC building code. But US code states 1" subfloor. A new problem has arisen about tiling over plywood... I forgot to mention this is also a heated floor which would create a lot more flex with the...

Can thinset be sanded off plywood? [ 3 Answers ]

I've removed old tile and hardibacker from my plywood subfloor. There is still some thinset stuck to the plywood. Since we are installing hardwood in this location, it needs to be smooth. Can the thinset be sanded? Any particular type of paper recommended? Thanks!

Tiling over plywood [ 2 Answers ]

The bathroom floor to be tiled is 5/8" subfloor with 1/4" ply ontop screwed every 6 inches.Iam trying to convince carpenter that this does not meet code, nor is it a proper base for tiling. I want him to put down hardibacker (1/4") but he has convinced home-owners not necessary. What do I do?...

Question regarding plywood [ 3 Answers ]

I will be installing porcelain tiles in a small bath and want to use 3/4" exterior plywood over the subfloor. I will covering that with Ditra matting. I went to Home Depot and the only 23/32" I could find was "Certified sanded". It looked real nice on the sanded side but it was not tonque and...


View more questions Search