    i am pouring a 25' x 36' garage slab do i need footers?
    I live in Northern MO and I'm getting ready to pour a 25'x36' garage slab. My first question is do I need both piers and 12" footer? And will a 4" slab be OK for a 3/4 ton truck?
    KBC's Avatar
    KBC Posts: 2,550, Reputation: 487
    Ultra Member
     
    #2

    Mar 27, 2010, 02:37 PM
    As long as you add reinforcing mesh/wire/rebar,etc.and as long as you have sufficient stone base.

    This is a floating pad.

    I used 2 X 6 for the perimeter and scooped the earth down at the edges,then stone sloping to the edge making it deeper than the body,about 12" in,I did this for a 24' X 40' pad,broken into 4 parts on the 40' run(expansion/stress lines)
    scotty396's Avatar
    scotty396 Posts: 32, Reputation: 1
    Junior Member
     
    #3

    Mar 27, 2010, 05:11 PM

    My contractor want to put a 12" footer all the way around the edges plus 18" x 30" deep piers every 5' below the footer. Just sound like overload to me... Also, I am attaching this structure to a exsiting structure that has only a 4" floating slab. Does that sound like a problem? My plan is to dig and level down far enough to use 2x12's as my forms then putting in 71/2" of crushed rock packed then 1/2" rebar and 4" of concrete. And follow your advice by leaving the edges clear of so much crushed rock. Is your slab capable of holding a heavy 3/4 ton truck?
    KBC's Avatar
    KBC Posts: 2,550, Reputation: 487
    Ultra Member
     
    #4

    Mar 27, 2010, 06:06 PM

    The building I made mine for holds large equipment,loaders,1 ton trucks,etc.. It's at a grain elevator.

    To attach to the existing structure,I would drill and install rebar to the existing concrete,then tie the new rebar to those.

    I only used wire for my reinforcement,It hasn't budged once,no cracks,no separation.

    A truck's weight is so spread out on the tires,you really have little to worry about as far as weight issues, 4" concrete is more than enough.

    I see no reason to go with a 2 X 12,that is overkill.Unless the ground water table is near the surface?or there is some kind of slope in the yard near this project?

    Piers,, I can't see ANY reason for them, is there going to be some kind of posts in the middle, or some kind of weight bearing on the pier locals?

    If no to all these, it's overkill and not in your best interest to stay with this contractor, get other bids.
    manhattan42's Avatar
    manhattan42 Posts: 143, Reputation: 11
    Junior Member
     
    #5

    Mar 31, 2010, 04:08 AM

    There is not enough information to answer the original psoter's question.

    The need for piers under the footings may the result of point loads that may be imposed from a post-and-beam structure and may be required because of the existing soil conditions.

    The original poster needs a design professional to determine what may be needed along with the local code office to determine what will be required.

    Connecting this structure to another floating structure with questionable construction remains suspect at best.

    The original poster needs a design professional to answer his questions... and should do nothing until the design is confirmed by the local code professionals.
    parttime's Avatar
    parttime Posts: 1,440, Reputation: 113
    Ultra Member
     
    #6

    Mar 31, 2010, 04:59 AM

    I'm curious about the 25' measurement, seems like building in a lot of waste wood. Or not?
    scotty396's Avatar
    scotty396 Posts: 32, Reputation: 1
    Junior Member
     
    #7

    Mar 31, 2010, 05:45 PM

    I am building a three car garage with exterior walls only, there will be no center post. The reason for the 25' dem. Is that's how wide the other building is. I asked a engineer I know from TX and he said I would only need peirs under the footings if I was building on a hill or a slope of some kind to stop the slab fron moving horizontaly. The code for home construction in Pasadena, TX if 12"x12" footer around the edges and where there are load bering walls. He recommends I pour a 4" slab with thickend edges of 12" wide and 8" deep.
    Papa_G's Avatar
    Papa_G Posts: 1, Reputation: 1
    New Member
     
    #8

    Oct 9, 2010, 07:35 AM
    The key words were location, Pasadena Tx is flat sandy base which should only require footings, further north near Dallas the land has more clay that moves with the seasons makes it more prone to use piers. A 4" slab with proper reinforcement should hold up fine, the question is do you want to have just enough or a little safety zone for unseen use later? After slab is poured to help relieve spider cracks you can also cut relief lines in surface to relieve stress. Pouring later in the afternoon or evening and not in the hot sun can also help relieve
    The stress letting the concrete cure longer. When attaching to an existing structure make sure the ground is firmly compacted to eliminate any shifting and stress to existing foundation. Iam in the process of repairing this exact problem made by a house builder, doing it right the first time is easier than trying to repair it years down the road!

Not your question? Ask your question View similar questions

 

Add your answer here.


Check out some similar questions!

Pouring a cement slab [ 1 Answers ]

I just removed my rotten floor in my home I just purchased. It's an 80yr old home which I plan to resale. I added plumbing fixtures in one room which is now the bathroom and as well in another room for a future kitchen. Here is the dilema, I have about 8" to get to where i want to be in height. I...

From Pouring Garage Pad to Construction of Garage [ 4 Answers ]

How long to you have to wait after pouring the cement garage pad before you can begin construction on the garage?

Pouring new Concrete slab over OLD basement slab [ 2 Answers ]

I have a house placed on its exsisting foundation and basement concrete floor in 1934. The floor is solid, uncracked, and level but has several areas that are very uneven. To the point, the basement is unusable for living space. Is it possible, and reasonable, to pour a new slab over the...

Pouring interior concrete slab over existing, cracked concrete slab [ 4 Answers ]

I am turning part of my carport into a new living room. I am going to pour a concrete slab about 4 inches thick over the existing carport floor which is a concrete slab. The existing slab has a few cracks, the largest of which is about an 1/8in. Wide and raised about an 1/8in. What would be the...

Pouring concrete slab outside garage [ 2 Answers ]

Hi All, I am replacing my garage door with a wall and 36" wide steel door to make it a main entrance to the house in the winter and also into a workshop area. It has been recommended that I pour a concrete slab across the front of the garage for the wall to sit on and have that slab just high...


View more questions Search