Ask Experts Questions for FREE Help!
  Advanced
Register  |  Log in  
   Ask    
 Answer  
  Help  

Ask QuestionsprogressAnswer QuestionsprogressBuild ReputationprogressBecome an Expert
 
Free Answers in 3 Easy Steps

Register Now
3 Steps

At Ask Me Help Desk you can ask questions in any topic and have them answered for free by our experts. To ask questions or participate in answering them you must register for a free account. By registering you will be able to:
  • Get free answers from experts in any of our 300+ topics.
  • Accept money for answers that you provide.
  • Communicate privately with other members (PM).
  • See fewer ads.

Home > Home & Garden > Cars & Trucks   »   Tracking an open ingnition circuit in a 92 Accord

 
Question Tools Search this Question Display Modes
Question
 
 
#1  
Old Nov 24, 2007, 03:58 PM
popsbluejazz
New Member
popsbluejazz is offline
 
Join Date: Nov 2007
Posts: 10
popsbluejazz See this member's comment history on his/her Profile page.
Tracking an open ingnition circuit in a 92 Accord

Thanks to all of you sharing their experience and especially to the expert advisers. I have a 92 Accord that died on the road one wet night (yes it rains here in Oregon). Someone said replace the fuel filter, and so I did (it was overdue anyway). Now I tested the spark plug wires and there is no spark. After reading some of the posts, I realized I should do the K test, and have the CEL light stay on after the 3 seconds. I also have been checking the voltage at the igniter, and have none. I also have no voltage at the yellow lead to the coil. The coil is shot, as the ohms are at infinity across 2 sets of terminals. I know I'm rambling, but can anyone suggest how to track an open circuit from the ingition coil to the ingnition switch??
It seems I have more information than the ability to process it properly.

Reply With Quote
 
     

Answers
 
 
Old Nov 24, 2007, 04:14 PM   #2  
txgreasemonkey
Cars & Trucks Expert
txgreasemonkey is online now
 
txgreasemonkey's Avatar
 
Join Date: Jun 2006
Location: Undisclosed, Republic of Texas
Posts: 4,625
txgreasemonkey See this member's comment history on his/her Profile page.txgreasemonkey See this member's comment history on his/her Profile page.txgreasemonkey See this member's comment history on his/her Profile page.txgreasemonkey See this member's comment history on his/her Profile page.
Since the CEL stays on, the problem is with fuses, ECM, main relay, or ignition switch. Therefore, check all under-dash and under-hood fuses with a test light or multimeter. Here's how:

http://www.askmehelpdesk.com/cars-tr...tml#post252145

Next, clean the 3-P main ECM ground on the thermostat housing, apply dielectric compound, and perform the K-Test on the ECM. There's a real possibility the ECM is shot. The main relay and ignition switch are not as problematic as fuses and ECM.

After you solve the problem at hand, the link below may help you "weatherize" your Accord for wet weather:

http://www.askmehelpdesk.com/cars-tr...tml#post520809

Comments on this post
popsbluejazz : I"m going to try the K test and see how it works. A direction is better than no direction.
  Reply With Quote
 
     
 
 
Old Nov 25, 2007, 02:28 PM   #3  
popsbluejazz
New Member
popsbluejazz is offline
 
Join Date: Nov 2007
Posts: 10
popsbluejazz See this member's comment history on his/her Profile page.
Thanks to The Lone Star TXGreasemonkey for leading me along the path to fix.
I did the K test on the ECM, and it had good voltage (about 5 v). That's between the MAP sensor (red/white) and the black probe grounded 1on the thermostat housing. Is that right? I saw the 3 P connector, but didn't know which lead to connect to if I was supposed to connect there.
I also jumped the diagnostic connector, and got an DTC 15 for ignition output signal. I also checked the fuse boxes, and the starter signal circuit (fuse #9) is dead (no voltage); this is in the under dash fuse box. Under the hood, my R and L headlight fuse circuits are also dead. The fuses are fine as I checkec them for continuity.
Does that help or confuse more? It seems there must be a connection between the ignition failure (DTC 15), the starter signal circuit failure (fuse 9), and the lack of voltage to the coil and ICM. Or have I been in the rain too long?
Thanks again for your help so far; it goes so much further than the manual (Haynes).
PopsBlueJazz
  Reply With Quote
 
     
 
 
Old Nov 25, 2007, 02:49 PM   #4  
txgreasemonkey
Cars & Trucks Expert
txgreasemonkey is online now
 
txgreasemonkey's Avatar
 
Join Date: Jun 2006
Location: Undisclosed, Republic of Texas
Posts: 4,625
txgreasemonkey See this member's comment history on his/her Profile page.txgreasemonkey See this member's comment history on his/her Profile page.txgreasemonkey See this member's comment history on his/her Profile page.txgreasemonkey See this member's comment history on his/her Profile page.
DTC 15 = Bad Ignition Control Module (ICM)

AutoZone can test the ICM for free, but my advice is to replace them every 120,000 miles or 10 years, whichever comes first. This is definitely part of your problem. Here's how to replace the ICM and coil (which I'd recommend you do, while you have the distributor open):

http://www.askmehelpdesk.com/cars-tr...tml#post265896

Be sure to clean the main ECM ground. After replacing the ICM, let me know if the CEL goes out after 2 seconds.
  Reply With Quote
 
     
 
 
Old Nov 25, 2007, 03:17 PM   #5  
Duane in Japan
Full Member
Duane in Japan is offline
 
Join Date: Oct 2007
Posts: 282
Duane in Japan See this member's comment history on his/her Profile page.
Your starter fuse and headlight fuse more than likely only get power when those items are energized. Some things on your car are power side controlled and some things on your car are ground side controlled.

Power does not go through these fuses until you put the key to the start position or until you actually turn the headlights on, use your voltmeter to test, not the ohmmeter while power is applied to the fuses.
  Reply With Quote
 
     
 
 
Old Nov 25, 2007, 07:34 PM   #6  
popsbluejazz
New Member
popsbluejazz is offline
 
Join Date: Nov 2007
Posts: 10
popsbluejazz See this member's comment history on his/her Profile page.
Thanks Duane in Japan for the reminder; much obliged.
Thanks again to TXGreasemonkey for the further direction.
My concern right now is that I have no voltage to the coil. I am pretty sure the coil is gone since the resistance is too high. But if I just replace the coil and ICM, what prevents the previous problem from recurring? Also, if I just replace the coil and ICM they most likely won't work due to lack of power still. Am I missing something here?
Confused in Oregon.
  Reply With Quote
 
     
 
 
Old Nov 26, 2007, 08:18 AM   #7  
Duane in Japan
Full Member
Duane in Japan is offline
 
Join Date: Oct 2007
Posts: 282
Duane in Japan See this member's comment history on his/her Profile page.
Extremely high (secondary ignition system) resistance can take out a coil. For years folks have put a screwdriver in the end of the plug wire and tried to jump a spark from the side of the screwdriver to ground, maybe trying to jump a spark across a half inch gap, this could take out the coil on many cars, GM HEI comes to mind. It is a good thing that you want to replace them as a set, the coil and ICM that is, that is a good plan in my book, expensive but safer.

You have no power on the black / yellow wire going to the distributor, this wire goes to both the coil and ignitor but you knew that. Do a continuity test on the black / yellow wire going back to the ignition switch. Jumper (back probe) battery power to the black / yellow wire at the distributor connector and see if it starts.

Just remembered, did you disconnect the distributor connector and then test for power on the black / yellow terminal on the car side of the harness of course in case of a short inside the dizzy.
  Reply With Quote
 
     
 
 
Old Nov 26, 2007, 10:10 AM   #8  
popsbluejazz
New Member
popsbluejazz is offline
 
Join Date: Nov 2007
Posts: 10
popsbluejazz See this member's comment history on his/her Profile page.
I found out that my CEL light stays on if I leave the coil connector unplugged (probably a DUH for most of you folks). When I plug the connector back in, the CEL light goes out. I did try checking the voltage to the ICM unit inside the distributor after reconnecting both the connector and secondary coil lead to the coil, and it was still no volts. I will start to try finding the proper wire to check for continuity in the black/yellow, which becomes yellow after the coil. What it is when it gets to the ignition switch I'm not sure, but I'll check the wiring diagram, even though I don't trust Haynes very much. Especially after the Diagnostic code differences Txgreasemonkey turned me onto. Thanks to you Duane for all your assistance.
  Reply With Quote
 
     
 
 
Old Nov 26, 2007, 05:11 PM   #9  
Duane in Japan
Full Member
Duane in Japan is offline
 
Join Date: Oct 2007
Posts: 282
Duane in Japan See this member's comment history on his/her Profile page.
It should be blk/yel at the ignition switch, Honda uses this color for power on several systems coming off the fuse boxes or ignition switch.

Off of memory, there are four terminals on the ICM, three of them are side by side, the middle terminal is the power input, is this correct.

Did you try jumping power to the distributor connector blk/yel? Use a sewing needle to backprobe the pin. Dont puncture the wire insulation.
  Reply With Quote
 
     
 
 
Old Nov 27, 2007, 02:58 PM   #10  
popsbluejazz
New Member
popsbluejazz is offline
 
Join Date: Nov 2007
Posts: 10
popsbluejazz See this member's comment history on his/her Profile page.
You are right on, Duane. There are 3 terminals side by side and one on the end of the igniter. The middle one is the black/yellow and it has voltage now that I remembered to plug the coil back in before checking for voltage. Here's what I have checked on the igniter so far, and the results (with ignition switch on):
1. 12 V between the yellow/black (wire to the middle terminal) and ground.
2. 12 V between the light green (wire to the terminal toward the front of the car) and ground.
My Haynes manual says to check for continuity between the light green and the ECU. Also to check the resistance between the blue wire from the tachometer terminal and the igniter, but it doesn't say where on the igniter to check for resistance (of 1.1K to 3.3K Ohms).
To make everything just perfect, it says "If all the checks are OK, replace the igniter." This makes no sense to me, as if the checks are OK, the igniter would be OK.
Still confused in Oregon, but learning more with your great help.
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
Nordyne Furnace "burner limit circuit open", during A/C operation pawwright Heating & Air Conditioning 4 Sep 10, 2007 03:40 AM
Furnace "burner limit circuit open", How to fix? LuMax Heating & Air Conditioning 2 Feb 10, 2007 01:51 PM
Can an open ground reading on a grounded circuit mean a 240V line? LDRobinson Electrical & Lighting 2 Feb 7, 2007 06:27 AM
Outside GFI circuit - 15amp outlet on 20amp circuit Gabriel Electrical & Lighting 1 Jul 18, 2005 04:46 PM
Ingnition problem - 2000 Honda Civic Ex Tom Ric Cars & Trucks 1 Feb 3, 2005 07:09 PM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 06:20 AM.

Content Relevant URLs by vBSEO 3.0.0 RC6 © 2006, Crawlability, Inc.