    My trane furnace blower fan stops intermittently
    I have a 15 year old heat pump and electric furnace I am so proud of it lasting this long with no problems, but the blower motor will stop running about once a month usually when I most need it (meaning maybe it has stopped other times and I have not noticed it.) I can see the unit is still getting power to it as I have a UV light for mold and it is on and the heat pump fan is running outside the house. The only thing that I can do is turn off the breakers on the side of the unit, and turn them back on. Usually it takes 3 or 4 times. I wish I could tell you the longer I let it sit, the more frequently it comes back when I flip the breaker, but I usually let it sit for about a minute then try it, so I can't tell you if time setting with the breakers off helps or not. I assume there is a resettable breaker inside the unit that might be getting set off, but don't know where to get an exploded parts diagram for the furnace. Any help is appreciated!!
    drtom4444's Avatar
    drtom4444 Posts: 3,282, Reputation: 145
    Ultra Member
     
    #2

    May 30, 2011, 01:00 PM
    There are only three parts that could fail: the motor, the capacitor, and the relay. At times you can have a capacitor that is partially shorted. This costs about $5.00. You can check it with a meter and if it has no resistor between the two terminals it should read resistance and go to zero and when you switch lead position it will do the same. Otherwise it may be a bad fan motor which is heating up and opening the safety. Check the leads and see if they read any resistance to ground; if they do your motor is bad. In that case replace both motor and capacitor. DrTom4444
    ilovejunkfood's Avatar
    ilovejunkfood Posts: 2, Reputation: 1
    New Member
     
    #3

    May 30, 2011, 01:38 PM
    Thanks Tom I will check out those options

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

I have a trane eletric ignition heater and blower furnace is heating up but no blower [ 1 Answers ]

My thermostat is a white /rodgers module this clicks to start but no air blowing from the furnace in the attic which is a trane model and the same with cold air the thermostat clicks the ducane model outside whirs but no cols air.

Trane gas furnace stops sometimes [ 0 Answers ]

Dear help, My Trane gas furnace stops working some time to time and after play with the control in the room (manual) it works again. This happened a few times and I wonder if I need to replace the control in the room since it is relatively old. Thanks. Ellen

PVC Pipe Leakage, furnace Fan Does Not Stop, Blower Fan Works for 5 MIN and stops [ 1 Answers ]

1) I had water DRAINING from the furnace in the attic... it overflowed... the pan under furnace was beyond full. 2) I noticed leakage from one of the PVC pipes. 3) I simply replace the PVC pipe where water was leaking, but I forgot to put the PVC CEMENT. 4) I went to turn of the AC...

Fan motor intermittently stops [ 2 Answers ]

I found the problem when my ac lines froze... I checked the filter and A coils for dirt restricting air flow... all was clear. I then noticed when the ac unit is running the fan would quit running will the AC unit continued running. I then shut the air off and set the thermostat to fan ( so the...


View more questions Search